11. ENERGY SAVER MODES
Basically, the function and performance of the energy saver mode in all
machine configurations are identical with the exception of the copier
configuration for the 230V machine. The following are the items which have
been changed.
1. Fusing temperature in the energy saver level 2
80°C (230V machine)
2. The recovery time from energy saver level 2
30 s (230V machine)
3. When the auto shut-off timer runs out in the copier configuration (230V
machine only)
When the auto shut-off timer runs out, the machine will enter the auto
shut off mode and the ac switch will turn off automatically.
NOTE: This function is necessary to meet new BAM regulations in
Germany (enforced from January, 1999). The new BAM
regulation requires low power consumption in the auto-shut off
mode (less than 2 W).
4. Power consumption in the copier configuration
Mode
AC Switch
Energy
Saver
On
Level 1
Energy
Saver
On
Level 2
SM
Main
Energy
Fusing
Switch
Saver LED
On
On
165°C
140°C
(115 V)
On
On
(230 V)
13-19
ENERGY SAVER MODES
Rev. 02/98
System
Lamp
+5V
The machine will
On
return to standby
mode if the DF is
lifted or an original is
placed in the ADF or
On
ARDF.
80°C
Note