    - 2 - TABLE OF CONTENTS A MESSAGE FROM THE PRESIDENT UNPACKING YOUR 107T SETTING UP YOUR MD 107T CONTROLS AND FUNCTIONALITY DISPLAYS AND METERS CHECKING OUT YOUR MD 107T TUNER REMOTE (OPTIONAL) RC6 REMOTE IMAGE TROUBLESHOOTING RECEPTION TECHNIQUES Antenna Cabling:...
  • Page 3: A Message From The President

    FM Tuner. This complete process will insure that your listening experience will be optimized for years. The front end of all Magnum Dynalab tuners is an exclusive “in house” designed and manufactured component, we are the only company in the world that does their own R.F.
  • Page 4: Unpacking Your 107T

    Any obvious dents or scuff marks should alert you to the possibility of damage. Carefully remove the MD 107T from the end caps and wrapping, inspect all sides. Pay special attention to the corresponding areas on the unit where damage was found to the shipping carton.
  • Page 5: Setting Up Your Md 107T

    Note: Many countries that use 220/230/240 volts have a special FM transmitter; tuning de-emphasis for these countries may be different. Please consult Magnum Dynalab for the correct usage. If your tuner is used in a country where the tuning de-emphasis is set incorrectly the sonic performance will be...
  • Page 6: Controls And Functionality

    - 6 - CONTROLS AND FUNCTIONALITY A. POWER – Turns the power (AC) on and off to your tuner, with the optional remote system this switch must be left in the “OFF” position. B. MUTE – In the “ON” position, a limit is now placed on your tuner. While scaling up and down the FM dial, weak stations will be overlooked so that no alarming noises will be heard while looking for programs.
  • Page 7: Displays And Meters

    - 7 - DISPLAYS AND METERS H. SIGNAL STENGTH– This meter readout indicates the amount of signal the tuner is receiving, the higher the better. This will never read “100”. I. MULTI-PATH/SIGNAL METER - This meter indicates the amount of multi-path, the lower the reading the better.
  • Page 8: Checking Out Your Md 107T

    3. Place your bandwidth switch (E on diagram) to BW1. 4. Place your Mute switch (B on diagram) to “ON” position. 5. On your preamplifier/ integrated amplifier select the input that your MD 107T tuner is connected to. 6. Rotate the tuning knob on your tuner (F on diagram), or adjust frequency using...
  • Page 9: Tuner Remote (Optional)

    7. To turn your tuner off, push the “TUNER OFF” button until you see the tuner turn off. ** If you have purchased the optional DAC upgrade to the MD 107T, you may switch between inputs using the left knob or your remote.
  • Page 10: Rc6 Remote Image

    - 10 - RC6 REMOTE...
  • Page 11: Troubleshooting

    - 11 - TROUBLESHOOTING PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION • Power cord • Connect power cord No sound, meter • Check AC source lights are not on disconnected • Power off at source • Interconnect not • Verify installation of interconnects No sound, meter •...
  • Page 12: Reception Techniques

    Magnum Dynalab offers two Yagi antennae, the MD 6 FM or MD 10 FM Vertical ½ Wave - This design offers ease of installation and operation. This type of antenna is omni-directional, which means that it picks up stations coming from all directions.
  • Page 13: Fm Reception Aids And Accessories

    Magnum Dynalab offers the MD ST-2, an excellent vertical ½ wave antenna Folded Di-Pole - This is the most common and simplest of all antennas, most people are familiar with the 79 cent piece of wire you received with most electronics gear (generally provided with a tuner or receiver).
  • Page 14: Product Specifications

    (min) 0.92 mA Anode current (2) (max) 1.07 mA (min) 0.92 mA Total harmonic distortion < 1.8% Tubes position 1 and 2 MD Reference 6922 MAGNUM DYNALAB LTD. RESERVES THE RIGHT TO CHANGE OR MODIFY THE SPECIFICATIONS WITHOUT FURTHER NOTICE...
  • Page 15: Safety Sheet

    - 15 - SAFETY SHEET IMPORTANT SAFETY INSTRUCTIONS 1. KEEP THESE INSTRUCTIONS 2. HEED ALL WARNINGS 3. FOLLOW ALL INSTRUCTIONS 4. DO NOT USE THIS APPARATUS IN WATER 5. CLEAN ONLY WITH DRY CLOTH 6. DO NOT BLOCK ANY VENTILATION OPENINGS, INSTALL IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS.
  • Page 16: Limited Warranty

    LIMITED WARRANTY Register your product at www.magnumdynalab.com Magnum Dynalab Ltd. herein referred to as the “manufacturer” guarantees this product to be free of defect in both material and workmanship and agrees to remedy any such defect or replace any defective component at no charge for a period of two years from date of sale to the first end user.