Replacing A Dc Power Supply In The E4G-400 Router; Removing The Power Supply - Extreme Networks E4G Series Installation Manual

Hide thumbs Also See for E4G Series:
Table of Contents

Advertisement

Chapter 4: Maintenance Procedures

Replacing a DC Power Supply in the E4G-400 Router

In a redundant power configuration, you can replace one E4G-400 DC power supply without powering
down the router.
You need the following tools and materials to replace a 300 W DC power supply:
#1 Phillips screwdriver
Torque screwdriver and wrench or torque driver with attachments for tightening screws and nuts
Thermal protective gloves (required for removal of a power supply)
WARNING!
Be sure to disconnect all power cables before you disconnect the chassis ground wire.

Removing the Power Supply

To remove an installed 300 W DC power supply:
1 De-energize the DC circuit.
2 Disconnect the DC power cables as follows:
a Slide the cover off the terminal block.
b Loosen the screws that secure the cable terminals to the terminal block.
c Slide the wires out from under the captive washers.
3 Disconnect the ground wire as follows:
a Remove the screw that secures the ground wire to the power supply.
b Move the wire away from the power supply.
4 Push the latching tab to the left as you pull outward on the handle to disengage the power supply
internal connectors (see
Figure 44: Removing a DC Power Supply
5 Carefully slide the power supply the rest of the way out of the router.
74
Figure
44).
SH_212
E4G Series Routers Hardware Installation Guide