Panasonic CS-RE18JKX-1 Service Manual page 53

Air conditioner indoor unit outdoor unit
Hide thumbs Also See for CS-RE18JKX-1:
Table of Contents

Advertisement

15.5.6. H19 (Indoor Fan Motor – DC Motor Mechanism Locked)
Malfunction Decision Conditions
• The rotation speed detected by the Hall IC during fan motor operation is used to determine abnormal fan motor (feedback of
rotation > 2550rpm or < 50rpm).
Malfunction Caused
• Operation stops due to short circuit inside the fan motor winding.
• Operation stops due to breaking of wire inside the fan motor.
• Operation stops due to breaking of fan motor lead wires.
• Operation stops due to Hall IC malfunction.
• Operation error due to faulty indoor unit PCB.
Troubleshooting
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-re18jkx-1Cs-re24jkx-1Cu-re24jkx-1

Table of Contents