Panasonic CS-RE18JKX-1 Service Manual page 36

Air conditioner indoor unit outdoor unit
Hide thumbs Also See for CS-RE18JKX-1:
Table of Contents

Advertisement

1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated
above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1
below. When the air conditioner is stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and the positions
of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the vane will shift to close
position.
12.2.2. Horizontal Airflow
1. Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the angles as
stated below. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as
Figure 1 below.
Heating, with heat exchanger temperature
Cooling and Soft Dry
2. Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below and the
positions of the vane are as Figure 2 above.
Pattern
Airflow Direction
Patterns at Remote
Control
Vane Angle (°)
Operation Mode
1
2
90
68
36
Vane Angle (°)
A
68 ~ 112
B
90
68 ~ 112
3
4
78
102
5
112