Toshiba RAS-16SKV2-E1 Service Manual page 82

Toshiba split type air conditioner service manual
Table of Contents

Advertisement

11-8-5. Checking Method for Each Part
No.
Part name
1
Electrolytic capacitor
(For raising pressure, smoothing)
2
Converter module
1. Turn OFF the power supply breaker.
2. Discharge all three capacitors completely.
3. Check that safety valve at the bottom of capacitor is not broken.
4. Check that vessel is not swollen or exploded.
5. Check that electrolytic liquid does not blow off.
6. Check that the normal charging characteristics are show in
continuity test by the tester.
C12
C13
C14
C12, C13, C14 → 500µF or 760µF/400V
1. Turn OFF the power supply breaker.
2. Discharge all three capacitors completely.
3 Check that the normal rectification characteristics are shown in continuity
test by the tester.
1
2
Diode check
Tester rod
e
d
~
\
1
d
~
\
2
~
\
1
e
~
\
2
– 82 –
FILE NO. SVM-11029
Checking procedure
Case that product is good
Pointer swings once, and
returns slowly. When
performing test once again
MCC-5009
under another polarity, the
Soldered
pointer should return.
surface
~
~
+
1 2 3
4
(DB01)
Resistance value
in good product
50kΩ or more
(0Ω in trouble)