10. Record of Use check

Page 4F
Address
Function
94
Recording counter
95
(Hexadecimal)
96
97
Using method:
1) The recording counter data is displayed at page: 4F, addresses: 94 to 97. These data are named D
2) Calculate the recording counter (N) using following equation. (Hexadecimal calculation)
× 100 + D
N = D
+ D
97
96

11. Self Diagnostics Log check

Page 20
Address
Initial value
B0
00
B1
00
B2
00
B3
00
B4
00
B5
00
B6
00
B7
00
B8
00
*1: "C" t "01", "E" t "03"
Using method:
1) The self diagnostics log is displayed at page: 20, addresses: B0 to B5.
Note: These data will be erased when the lithium battery (LR-018 board) is removed.
Address 94 to 97
Remarks
1000000-digit and 1000000-digit
1000000-digit and 10000-digit
1000-digit and 100-digit
10-digit and 1-digit
× 10000 + D
× 1000000
95
94
Address B0 to B8
Function
"Repaired by" code (Occurred 1st time) *1
"Block function" code (Occurred 1st time)
"Detailed" code (Occurred 1st time)
"Repaired by" code (Occurred 2nd time) *1
"Block function" code (Occurred 2nd time)
"Detailed" code (Occurred 2nd time)
"Repaired by" code (Occurred 3rd time) *1
"Block function" code (Occurred 3rd time)
"Detailed" code (Occurred 3rd time)
6-42
, D
, D
and D
respectively.
94
95
96
97