Bru-300/300P Sd Optical Multiplex Unit For Use With The Brc-300/300P - Sony BRC-H700 System Manual

Brc series
Hide thumbs Also See for BRC-H700:
Table of Contents

Advertisement

Pin No.
Signal
Pin No.
1
Pr/R
9
2
Y/G
10
3
Pb/B
11
4
12
GND
5
13
GND
6
14
GND
7
GND
15
8
GND
VISCA RS-232C IN connector
8
Connect to the RM-BR300 Remote Control Unit.
When you join multiple cameras, connect it to
the VISCA RS-232C OUT connector of the previ-
ous camera in the daisy chain.
VISCA RS-232C OUT connector
9
When you join multiple cameras, connect it to
the VISCA RS-232C IN connector of the next
camera in the daisy chain.
VISCA RS-422 connector
10
VISCA FUNCTION switches
11
Switch 1
(RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
Switch 2
(Communication baud rate selector)
Set to ON for 38400 bps, or OFF for 9600 bps.
Switches 3 to 5
(Camera address selectors)
Set the address of the camera. Normally set to
0. With this setting, addresses are assigned to
the cameras automatically in the connected
order by pressing the POWER button while
holding down the RESET button on the
RM-BR300 Remote Control Unit. You can assign
the camera address, 1 to 7, manually by setting
these selectors as follows:
Camera
0
1
2
address
Switch 3 OFF
ON
OFF
Switch 4 OFF
OFF
ON
Switch 5 OFF
OFF
OFF
Please note that the same camera address
Note
cannot be assigned to two or more different
cameras.
Switch 6
(59.94i/50i signal format selector)
Set to ON for output of 50i signal format, or OFF
for output of 59.94i signal format.
Please further note that you must set the switches
Note
before you turn on power to the multiplex unit.
Signal
NC
GND
GND
NC
HD-OUT
Tri-level Sync/Bi-level VD
NC
3
4
5
6
7
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
5.2.2 BRU-300/300P SD Optical
Multiplex Unit for use with the
BRC-300/300P
Rear
1
IN EXT SYNC OUT
S VIDEO
3
4
5
6
Card slot
1
AC IN connector
2
EXT SYNC IN connector
3
EXT SYNC OUT connector
4
Composite video output connector
5
S-VIDEO connector
6
VISCA RS-422 connector
7
VISCA FUNCTION switches
8
Switch 1
(RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
Switch 2
(Communication baud rate selector)
Set to ON for 38400 bps, or OFF for 9600 bps.
Switches 3 to 5
(Camera address selectors)
Set the address of the camera. Normally set to
0. With this setting, addresses are assigned to
the cameras automatically in the connected
order by pressing the POWER button while
holding down the RESET button on the
RM-BR300 Remote Control Unit. You can assign
the camera address, 1 to 7, manually by setting
these selectors as follows:
Camera
0
1
2
address
Switch 3 OFF
ON
OFF
Switch 4 OFF
OFF
ON
Switch 5 OFF
OFF
OFF
Please note that the same camera address
Note
cannot be assigned to two or more different
cameras.
VISCA RS-232C IN connector
9
Connect to the RM-BR300 Remote Control Unit.
When you join multiple cameras, connect it to
the VISCA RS-232C OUT connector of the
previous camera in the daisy chain.
2
~
AC IN
FUNCTION
IN
OUT
1
6
VISCA RS-422
VISCA RS-232C
CAMERA
7
8
9 10 11
3
4
5
6
7
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
Switch 6 is not used.
Location and Function of Parts