Connect Vent; Level Dryer - Whirlpool WGD7990X Installation Instructions Manual

Gas dryer
Hide thumbs Also See for WGD7990X:
Table of Contents

Advertisement

Available languages

Available languages

6.
Turn on cold water faucet
Check that the water faucets are turned on.
7.
Check for leaks
Check for leaks around "Y" connector, faucet, and hoses.
NOTE: Replace inlet hoses after 5 years of use to reduce the risk
of hose failure. Record hose installation or replacement dates on
the hoses for future reference.
Periodically inspect and replace hoses if bulges, kinks, cuts,
wear, or leaks are found.

CONNECT vENT

1.
Connect vent to exhaust outlet
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
14
2.
Move dryer to final location
Move dryer to final location. Avoid crushing or kinking vent.
After dryer is in place, remove cardboard from under the dryer.

LEvEL DRYER

1.
Level Dryer
Place level here
Check levelness of dryer from side to side. Repeat from
front to back.
NOTE: The dryer must be level for the moisture sensing
system to operate correctly.
Not Level
Place level here
LEVEL
Not Level