Whirlpool WGD7800XB0 Installation Instructions Manual

Whirlpool WGD7800XB0 Installation Instructions Manual

27" gas dryer
Table of Contents

Advertisement

Available languages

Available languages

DRYER INSTALLATION INSTRUCTIONS
GAS (U.S_. AND CANADA)
ELECTRIC (CANADA ONLY)
INSTRUCTIONS D'INSTALLATION DE LA SI_CHEUSE
.&. G AZ (l_.-U. ET CANADA)
I_LECTRIQUE (CANADA UNIQUEMEN'r)
Para una version de estas intrucciones en espaSol, visite www.Whirlpool.com
TABLE OF CONTENTS
DRYER SAFETY ..............................................................................
2
................................................
4
Tools and Parts ............................................................................
4
Optional Equipment .....................................................................
4
Location Requirements ................................................................
4
CANADA ONLY .......... 6
Electrical Requirements ...............................................................
6
GAS DRYER POWER HOOKUP ....................................................
7
Gas Supply Requirements ...........................................................
7
Make Gas Connection .................................................................
8
VENTING .........................................................................................
8
Venting Requirements ..................................................................
8
Plan Vent System .........................................................................
9
Install Vent System .....................................................................
11
INSTALL LEVELING LEGS ...........................................................
11
CON N ECT VENT ...........................................................................
11
CONNECT INLET HOSES (STEAM MODELS) ........................... 11
LEVEL DRYER ..............................................................................
12
.......................................................
12
REVERSE DOOR SWING .............................................................
12
..................................................................
14
Dryer Operation ..........................................................................
14
Dryer Results ..............................................................................
15
TABLE DES MATIERES
SI_CURITI_ DE LA SI_CHEUSE ....................................................
16
EXIGENCES D'INSTALLATION ...................................................
18
Outillage et pieces ......................................................................
18
#quipement facultatif .................................................................
18
Exigences d'emplacement .........................................................
18
RACCORDEMENT
DE L'ALIMENTATION
.&,LA
SI_CHEUSE I_LECTRIQUE ...........................................................
20
electriques ..........................................................
20
.&,LA SI_CHEUSE .&, G AZ ..............................................................
21
Alimentation en gaz ....................................................................
21
Raccordement au gaz ................................................................
22
E'VACUATION ................................................................................
23
Exigences concernant I'evacuation ........................................... 23
Planification du systeme d'evacuation ...................................... 24
Installation du systeme d'evacuation ......................................... 25
INSTALLATION DES PIEDS DE NIVELLEMENT ........................ 25
DU CONDUIT D'I_VACUATION .................. 26
(MODF:LES .& VAPEUR) ................................................................
26
RI'--GLAGE DE L'APLOMB DE LA SI_CHEUSE ........................... 27
ACHEVER L'INSTALLATION .......................................................
27
DE LA PORTE ............. 28
DEPANNAGE .................................................................................
29
de la secheuse ................................................
29
Resultats de la secheuse ...........................................................
30
W10261614A
W10267631A - SP

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool WGD7800XB0

  • Page 1: Table Of Contents

    ELECTRIC (CANADA ONLY) INSTRUCTIONS D'INSTALLATION DE LA SI_CHEUSE .&. G AZ (l_.-U. ET CANADA) I_LECTRIQUE (CANADA UNIQUEMEN'r) Para una version de estas intrucciones en espaSol, visite www.Whirlpool.com TABLE OF CONTENTS TABLE DES MATIERES SI_CURITI_ DE LA SI_CHEUSE ............ DRYER SAFETY ................
  • Page 2: Dryer Safety

    DRYER SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word "DANGER"...
  • Page 3 WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, or to prevent property damage, personal injury, or death. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 4: Installation Requirements

    INSTALLATION REQUIREMENTS Tools and Parts Optional Equipment Gather the required tools and parts before starting installation. Read Refer to your Use and Care guide for information about the accessories available for your dryer. and follow the instructions provided with any tools listed here. For All Installations: Location Requirements •...
  • Page 5 Installation c learances Mobile home - Additional installation requirements The location must be large enough to allow the dryer door This dryer is suitable for mobile home installations. The installation to open fully. must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard Dryer Dimensions for Mobile Home Construction and Safety, Title 24, HUD Part 280)
  • Page 6: Electric Dryer Power Hookup- Canada Only

    ELECTRIC DRYER POWER HOOKUP- CANADA ONLY For further information, please reference the service numbers located in the "Assistance or Service" section. Electrical Requirements GROUNDING iNSTRUCTiONS [] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
  • Page 7: Gas Dryer Power Hookup

    GAS DRYER POWER HOOKUP • Lengths over 20 ft. (6.1 m) should use larger tubing and a different size adapter fitting. Gas Supply Requirements • If your dryer has been converted to use LP gas, 3/8" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft.
  • Page 8: Make Gas Connection

    3. Open the shutoff valve in the supply line. The valve is open when Dryer gas pipe the handle is parallel to the gas pipe. • The gas pipe that comes out through the rear of your dryer has a 3/8" male pipe thread. A.
  • Page 9: Plan Vent System

    A. Louvered hood style Vent products can be purchased from your dealer or by calling B. Box hood style Whirlpool Service. For more information, see the "Assistance C. Angled hood style or Service" section in your Use and Care Guide.
  • Page 10 Periscope Installation (For use with dryer vent to wall vent Optional exhaust installations. mismatch): Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch Part Number 4396011 - 18" (460 mm) to 29"(737 mm) mismatch Part Number 4396014 - 29" (737 mm) to 50" (1270 mm) mismatch Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible...
  • Page 11: Install Vent System

    Install Vent System CONNECT INLET HOSE 1. Install exhaust hood. Use caulking compound to seal exterior wall (STEAM MODELS) opening around exhaust hood. 2. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp. The dryer must be connected to the cold water faucet using the new inlet hoses.
  • Page 12: Level Dryer

    9. Attach other end of long hose to fill valve at bottom of dryer back panel. Screw on coupling by hand until it is seated on fill valve COMPLETE INSTALLATION connector. 1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.
  • Page 13 3. Loosen the top screw from each of the 2 hinges in Step 2. 3. Reinstall the door strike and cosmetic screw on the opposite side of dryer door opening from where they were removed. NOTE: Door strike and plugs must be on the same side of the dryer door opening.
  • Page 14: Troubleshooting

    Hang door by placing screw heads into top slotted holes 7. Close door to engage door strike. of hinges and slide door down. Align bottom screw holes in hinge and door. Install two bottom screws. Tighten all hinge screws. TROUBLESHOOTING First try the solutions suggested here and possibly avoid the cost of a service call...
  • Page 15: Dryer Results

    Is the exhaust vent diameter the correct size? Use 4" (102 mm) diameter vent material. Dryer Results Is the dryer located in a room with temperature below 45°F (7°C)? Clothes are not drying satisfactorily, drying times are too Proper operation of dryer cycles requires temperatures above long, or load is too hot 45°F (7°C).
  • Page 16: Si_Curiti_ De La Si_Cheuse

    SI CURITI DE LA SI CHEUSE Votre s_curit_ et celle des autres est tr_s importante. Nous donnons de nombreux messages de s6curit6 importants darts ce manuel et sur votre appareil m6nager. Assurez-vous toujours lire tousles messages de s6curit6 et de vous y conformer. Voici le symbole d'alerte de s6curit6.
  • Page 17 AVERTISSEMENT • Pour votre s_curite, les renseignements dans ce manuel doivent _tre observes pour reduire au minimum les risques d'incendie ou d'explosion ou pour eviter des dommages au produit, des blessures ou un d6c_s. - Ne pas entreposer ou utiliser de I'essence ou d'autres vapeurs...
  • Page 18: Exigences D'installation

    EXIGENCES D'INSTALLATION Les installations pour maison mobile necessitent un systeme d'evacuation en metal disponible chez le marchand chez qui vous Outillage et pi ces avez achete votre secheuse. Pour en savoir plus, veuillez consulter Rassembler les outils et pieces necessaires avant de commencer la section "Assistance ou service"...
  • Page 19 Ne pas faire fonctionner la secheuse & des temperatures inferieures & 45°F (7°C). P, des temperatures inferieures, la secheuse risque de ne plus s'arr_ter & la fin d'un programme automatique. Les temps de sechage risquent alors d'augmenter. 48" >-- La secheuse ne doit pas _tre installee ou remisee dans un endroit (310 c ra 2) oQ elle sera exposee &...
  • Page 20: Si_Cheuse I_Lectrique

    RACCORDEMENT DE L'ALIMENTATION LA SI CHEUSE I LECTRIQUE Pour en savoir plus, veuillez vous reporter aux numeros de service qui se trouvent & la section "Assistance ou service" dans le Guide Specifications lectriques d'utilisation et d'entretien. iNSTRUCTiONS DE LiAiSON A LA TERRE [] Pour une s6cheuse reli6e &...
  • Page 21: La Si_Cheuse .&, G Az

    RACCORDEMENT DE L'ALIMENTATION LA SI CHEUSE Canalisation d'arriv_e de gaz Alimentation en gaz • La canalisation doit comprendre un connecteur obture (filetage NPT 1/8" ou plus) accessible pour le raccordement de I'instrument de mesure immediatement en amont de la connexion d'alimentation en gaz de la secheuse (voir I'illustration suivante).
  • Page 22: Raccordement Au Gaz

    On doit utiliser une combinaison de raccords de tuyauterie Exigences concernant I'alimentation du br_leur pour raccorder la secheuse & I'alimentation en gaz existante. On voit ci-dessous une illustration d'un raccordement Altitudes sup_rieures a 10 000 pi (3048 m) : recommand& Le raccordement peut varier, selon le type, la dimension et I'emplacement...
  • Page 23: E'vacuation

    B. Style de clapet de type boPte C. Style de clapet inclin# On peut se procurer les produits d'evacuation aupres du marchand ou en tel6phonant & Whirlpool Service. Pour plus Terminer le conduit d'evacuation par un clapet de decharge de renseignements, voir la section "Assistance...
  • Page 24: Planification Du Systeme D'evacuation

    Installations d'_vacuation facultatives. • Le clapet de decharge doit _tre situe & au moins 12" (305 mm) au-dessus du sol ou de tout autre objet susceptible de se trouver sur le trajet de I'air humide rejete (par exemple, fleurs, roches ou arbustes, limite de la neige, etc.).
  • Page 25: Installation Du Systeme D'evacuation

    • Installation avec periscope (pour utilisation en cas de Tableau des syst_mes d'_vacuation non-concordance de la bouche de decharge de la secheuse REMARQUE : Les conduits d'evacuation par le c6te et par le bas avec la bouche d'evacuation murale) • comportent un changement de direction &...
  • Page 26: Raccordement Du Conduit D'i_Vacuation

    2. Saisir fermement la secheuse par la caisse (ni par le dessus 4. _, I'aide d'une pince, serrer les raccords en effectuant deux tiers ni par le panneau de commande). Deposer delicatement de tour supplementaires. la secheuse sur le carton. Voir I'illustration. 3.
  • Page 27: Ri Glage De L'aplomb De La Si Cheuse

    10. Terminer le serrage des raccords - deux tiers de tour supplementaires avecu un pince. ACHEVER L'INSTALLATION REMARQUE. Ne pas serrer excessivement. Le raccord risque d'etre endommag& 1. Verifier que toutes les pieces sont maintenant installees. S'il 11. Verifier que les robinets d'eau sont ouverts. reste une piece, passer en revue les differentes etapes pour decouvrir laquelle aurait ete oubliee.
  • Page 28: Inversion Du Sens D'ouverture De La Porte

    Inversion de la g_che INVERSION DU SENS 1. Retirer la g&che de la porte de la secheuse. 2. Retirer la vis cosmetique & I'oppose de la g&che de la porte. D'OUVERTURE DE LA PORTE Le sens d'ouverture de la porte peut _tre change du c6te droit au c6te gauche, si desir&...
  • Page 29: Depannage

    Installer les vis dans les trous superieurs de la porte destines le bas. Aligner les trous de vis inferieurs dans la charniere & la pose des charnieres. Ne pas serrer les vis. Laisser et la porte. Fixer deux vis inferieures. Serrer toutes les vis de la charniere.
  • Page 30: Resultats De La Secheuse

    R sultats de la s cheuse Le s_chage des v_tements n'est pas satisfaisant, les dur_es de s_chage sont trop Iongues ou la charge est trop chaude • Le filtre a charpie est-il obstru_ de charpie? Le filtre & charpie dolt _tre nettoye avant chaque charge. Risque d'explosion Garder les mati_res et les vapeurs inflammables, telle...
  • Page 31 NOTES...
  • Page 32 W10261614A W10267631A - SP 11/09 '_) 2009 Whirlpool Corporation. Printed in U.S.A. All rights reserved.

This manual is also suitable for:

Wgd7800xl0Wgd7800xw0Wgd7400xw0Wgd7300xw0Wgd7600xw0

Table of Contents