If appropriate, use the provided cable when connecting the AC PSU to the AC power source. Otherwise, the
installer should provide a standard IEC cable with the appropriate country plug. The 2-way connector should
be connected to the "power in + and –" terminals within the installation section of the IDU.
When using DC power the installer will need to provide a suitable 2 wire + earth cable capable of providing
12/24VDC nominal (11V min, 32V max) and 50W continuous / 80W for .25 seconds at switch-on at the IDU. The
positive and negative wires must be terminated using the connector from the AC PSU (provided). The 2-way
connector should be connected to the "power in + and –" terminals within the installation section of the IDU.
The earth should be connected to the earth tag inside the installation area (See Figure 14).
Shock Hazard
The Indoor Unit (IDU) contains low voltage that may cause serious injury if opened. Do not,
under any conditions, open or dismantle the IDU. Failure to follow these instructions could
result in serious injury or death.
Mounting the IDU
After a suitable location has been chosen, mount the IDU:
1. Layout the locations for the mounting screws, 3 total (see template in Appendix E). The IDU is mounted with
the connector edge facing down. Use the included template as a guide for drilling the mounting holes.
2. Drill and tap holes for M4 flange style mounting screws
a. Note: Alternative screws or screw / washer combination may be used.
Screw must fit into a 4.5 mm (.18 in.) hole.
3. Hold and screw the IDU against the wall.
Connecting Internal Connections to the IDU
Figure 14.
20