For cookers fitted with the optional glass lid the glass lid must always be in
the open position when the cooktop burners are operating.
First time use
Thoroughly clean the cooktop with warm soapy water prior to first use.

Cooktop burner operation

The individual burner positions on the cooktop are indicated by a graphic placed above the
burner control knob. Two further graphics indicate the 'full on' and 'turn down ' positions.
Ignition
1. To operate the individual cooktop burners press the appropriate control knob and
turn anti-clockwise to the spark symbol. Push to activate the electronic ignition.
2. Once the flame is stabalised turn the knob to the desired setting. Keep the knob
depressed for 5 seconds to activate the flame failure device.
3. If the flame goes out repeat the procedure.
NOTE: If the burner does not ignite within 5 seconds, wait 5 minutes before reigniting.
Cooktop burner adiustments
The control knob is used
'High flame' graphic =
'Low flame' graphic = lowest output
Use the 'High flame' setting to bring the pan to the boil, then adjust the flame to maintain the
required pan temperature. Burner flames should be clear blue, with no yellow tipping. If the
burners show any abnormality check that the burner
satisfactory performance cannot be abtained after consulting the trouble shooting guide,
Cooktop burner operation
to adjust the flame of the gas burner.
highest output
heads
are correctly located. lf