Test Point Diagram Outdoor Controller Circuit Board - Mitsubishi Electric PUHZ-RP35VHA Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for PUHZ-RP35VHA:
Table of Contents

Advertisement

10-9. TEST POINT DIAGRAM
Outdoor controller circuit board
PUHZ-RP35/ 50/ 60/ 71/ 100/ 125/ 140VHA
PUHZ-RP100/ 125/ 140YHA
CNS
(Indoor/outdoor unit
connecting wire)
Communication
power supply
ZD71 Voltage
developed across:
16-30V DC
+
CNAC
2 to 4: Power supply for
outdoor controller
circuit board
(220V-240V AC)
1 to 3: Power supply for
indoor and outdoor unit
connection wire
(220V-240V AC)
CN2
Connect to the outdoor
power circuit board (CN2)
1-5:
Power circuit board
Transmitting signal to
the controller circuit board
(0-5V DC)
2-5: Zero cross signal
(0-5V DC)
3-4: Not used
(RP35-71VHA)
(RP100-140YHA)
18V DC
(RP100-140VHA)
6-5: 16V DC
7-5: 16V DC
[5: – 1,2,6,7: + ]
21S4
Four-way
valve
SV2
RP60-71 : Bypass valve
RP100-140 : Replace
valve
CN4
Transmission
to outdoor
power circuit
board (CN4)
CN52C
(Connect to the outdoor
noise filter circuit board
(CN52C))
Only for RP35-RP71VHA
(TEST POINT 2)
V
CC
(voltage between pins of C6B): DC 15V
CN51
External signal output
• Compressor operating signal
• Abnormal signal
<CAUTION> TEST POINT1 is high voltage.
63H
High pressure switch
SW10
SW9
Model select
CNDM
1 to 2: Input of silent mode
1 to 3: Input of external
contact point
64
(TEST POINT 1)
V
DC
(voltage between pins of C5E)
: DC250V-380V
CNDC
DC280V-380V
+
}
Connect from out-
door power circuit
board for RP·VHA,
connect from noise
filter board for
RP·YHA
(TEST POINT 3)
V
SP
(voltage between pins of
C5A, C5B): DC 0V (when
stopped), DC 1– 6.5V
(when operated)
(TEST POINT 4)
V
FG
(voltage between right
pins of PC5C and
PC5D, pin 3 and pin 4)
TH6
Thermistor
<Outdoor 2-phase pipe>
TH7
Thermistor<Outdoor>
TH3
Thermistor
<Outdoor pipe>
TH4
Thermistor
<Discharge>
LEV-A,-B
Linear expansion valve
63L
Low pressure switch
Only for RP100-140
SW5
Function switch
SW6
Model select
SW1
Forced defrost,
detect history
record reset,
refrigerant address
SWP
SW7
pump down
Demand control setting
SW4
Test operation
(CNDC)