SCHEMATIC DIAGRAM AND IN THE PARTS LIST ARE CRITICAL FOR RISK OF FIRE AND ELEC- TRIC SHOCK. REPLACE THESE COMPONENTS WITH ONKYO PARTS WHOSE PARTS NUMBERS APPEAR AS SHOWN IN THIS MANUAL. MAKE LEAKAGE-CURRENT OR RESISTANCE MEASUREMENTS TO DETERMINE THAT EXPO-...
3 7 63 1515 0 R-805TX SPECIFICATIONS Amplier Section 50 dB Quieting sensitivity FM: Mono 17.2 dBf, 2.0 µV (75 ohms) Power output Stereo 37.2 dBf, 20.0 µV (75 ohms) 20 watts per channel, min RMS, at 4 ohms, both channels driven 1 kHz, Captur e ratio with no mor e than 0.6% THD...
R-805TX 3 7 63 1515 0 SERVICE PROCEDURES 5. Changing the AM band step 1. Replacing the fuses The tuning step selector switch is not provided in this model. When you change the band step, change the parts as shown This symbol located near the fuses indicates that the below.
Page 4
INPUT selector OUTPUT OUTPUT ENERGY SA VE indicator ENERGY SA VE button ACOUSTIC PRESENCE button VOLUME control Remote control sensor TAPE This unit (R-805TX) TAPE ANTENNA For the Asian model: FM STEREO / AM TUNER AMPLIFIER VOLUME CAUTION: SPEAKER INPUT...
R-805TX 3 7 6 3 1 5 1 5 0 REMOTE CONTROLLER • Use the following buttons to control components that are connected to the - system. • You can control the other -connected components with the supplied remote controller.
R-805TX 3 7 6 3 1 5 1 5 0 PARTS LIST CAUTION: Replacement for transistor of mark *, if necessary must be made from the same bata group (H ) as the original type. REF.NO. PART NO. DESCRIPTION REF.NO.
Page 8
R-805TX 3 7 63 1515 0 IC BLOCK DIAGRAMS AND DESCRIPTIONS TC9184AP(ELECTRONIC TONE CONTROL) CK DATA STB LEVEL SHIFT BASS+ BASS+ BASS- BASS- TREBLE- TREBLE- TREBLE+ TREBLE+ Pin No. Symbol Function Power supply voltage terminals (Analog section) 2/15 BASS+...
Page 9
R-805TX TA7291S(VOLUME MOTOR DRIVER) 3 7 63 1515 0 Vref INPUT OUTPUT MODE OUT1 OUT2 STOP CW/CCW CCW/CW BRAKE REGU- OUT1 LATOR CCW: Counter-clockwise direction CW: Clockwise direction OUT2 PROTECTOR 10-BT-167GK(FL TUBE) TIMER TRACK AUTO MONO STEREO L 13942296513 W.DAY...
Page 19
R-805TX PACKING PROCEDURES 3 7 63 1515 0 1. Pad A outside Proceed the operation of step 1 to 6. : inside Top view outside Bottom view : outside Turn up L 13942296513 2. Pad B Proceed the operation of step 1 to 6.
Need help?
Do you have a question about the R-805TX and is the answer not in the manual?
Questions and answers