Heat pump outdoor units elite series r−410a - two−stage compressor
Hide thumbs Also See for XP16?024:
Table of Contents

Advertisement

FEATURES
CONTENTS
ARI Ratings
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Equipment Warranty
Compressor − limited warranty for ten years in
residential installations and five years in non-residential
installations.
All other covered components − five years in
residential installations and one year in non-residential
installations.
Refer to Lennox Equipment Limited Warranty certificate
included with unit for specific details.
Approvals
Certified in accordance with USE certification program
which is based on ARI Standard 210/240−2005.
Sound rated in Lennox reverberant sound test room in
accordance with test conditions included in ARI Standard
270−95.
Tested in the Lennox Research Laboratory environmental
test room.
Rated according to U.S. Department of Energy (DOE) test
procedures.
Heat pumps and components within bonded for
grounding to meet safety standards for servicing required
by UL and CEC.
Units are UL and ULC listed.
ISO 9001 Registered Manufacturing Quality System.
E
S
® certified units are designed to use less
NERGY
TAR
energy, help save money on utility bills, and help protect
the environment.
ApplicationS
SEER up to 17.0.
Heating COP up to 3.82.
HSPF (region IV) up to 8.70.
2 through 5 ton.
Single phase power supply.
Sound levels as low as 74 dB.
Vertical air discharge allows concealment behind shrubs
at grade level or out of sight on a roof.
Designed for applications with remotely located indoor air
handlers or add−on indoor coils with FM21
furnace control. See FM21
Also see Indoor Coils and Air Handlers sections for indoor
unit data.
Units shipped completely factory assembled, piped, and
wired. Each unit is test operated at the factory insuring
proper operation.
Installer must set heat pump, connect refrigerant lines,
and make electrical connections to complete job.
For expanded ratings, see www.lennoxdavenet.com.
XP16 − 2 to 5 Ton Heat Pump / Page 2
. . . . . .
Page 8
Pages 9−13
Page 6
Page 5
Pages 2−4
Page 7
. . . . . . . . . . . .
Page 8
Page 7
. . . . . . . . . . . . . . . . . .
Page 1
Page 5
Page 7
Page 5
®
dual fuel
®
bulletin, Controls section.
H
F
L
REFRIGERATION SYSTEM
Refrigerant
Non−chlorine, ozone friendly, R−410A.
Unit is factory pre−charged. See
Specification table.
Total system refrigerant charge is dependant on outdoor
unit size, indoor unit size and refrigerant line length. Refer
to charging procedures in the Installation Instructions to
determine correct amount of charge required.
B
Outdoor Coil Fan
Direct drive fan moves large air volumes uniformly
through entire condenser coil for high refrigerant cooling
capacity.
Vertical air discharge minimizes operating sounds and
eliminates damage to lawn and shrubs.
Fan motor has sleeve bearings and is inherently
protected.
Motor totally enclosed for maximum protection from
weather, dust and corrosion
Fan guard constructed of corrosion−resistant PVC
(polyvinyl chloride) coated steel.
Fan service access accomplished by removal of fan
guard.