Motorola ASTRO 25 User Manual page 27

Portable/mobile radios
Hide thumbs Also See for ASTRO 25:
Table of Contents

Advertisement

Fixed Structure
Codeplug Errors
ERROR - Cannot proceed
with FLASH Upgrade when
the codeplug has more than
one ASTRO System.\n
Please remove the additional
ASTRO Systems and try
again!
ERROR - Cannot proceed
with FLASH Upgrade when
the codeplug has more than
240 Conventional
Personalities.\n Please
remove the additional
Conventional Personalities
and try again!
ERROR - Cannot proceed
with FLASH Upgrade when
the codeplug has more than
15 Zones.\n Please remove
the additional Zones and try
again!
ERROR - Cannot proceed
with FLASH Upgrade when
the codeplug has more than
16 Channels in each Zone.\n
Please remove the additional
Channels and try again!
Troubleshooting Hints
Possible Corrective Actions
This error only appears in the portable when
upgrading to add the Conventional Radio Clon-
ing option. The codeplug in the radio must have
a special structure in order for the upgrade to
continue. This error is appears when the code-
plug has more than one ASTRO system.
This error only appears in the portable when
upgrading to add the Conventional Radio Clon-
ing option. The codeplug in the radio must have
a special structure in order for the upgrade to
continue. This error appears when the codeplug
has more than 240 Conventional Personalities.
This error only appears in the portable when
when upgrading to add the Conventional Radio
Cloning option. The codeplug in the radio must
have a special structure in order for the upgrade
to continue. This error appears when the code-
plug has more than 15 Zones.
This error only appears in the portable when
upgrading to add the Conventional Radio Clon-
ing option. The codeplug in the radio must have
a special structure in order for the upgrade to
continue. This error appears when the codeplug
has more than 16 Channels in a zone.
FLASHport User's Guide
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents