4-11. Wiring Optional 240 Volt Plug (119 172) For Connection To Bobcat, Trailblazer
Or Champion 10,000
Tools Needed:
3/16 in.
!
Engine Control Switch must be set at "RUN"
position − not "RUN/IDLE".
OM-237 974 Page 16
.
A complete Parts List is available at www.MillerWelds.com
3
4
7
240V
6
8
1
Green Or
Green/Yellow
!
Set generator Fine Adjustment Control to 10
for maximum auxiliary power, if applicable.
2
3
4
5
6
5
Plug Front
View
7
8
1
Input And Grounding
Conductors
2
Plug Wired for 240 V, 2-Wire
Load
3
Neutral (Brass) Terminal And
Prong (Not Used)
4
Load 1 (Brass)Terminal And
Prong
5
Load 2 (Brass) Terminal And
Prong
6
Ground (Brass) Terminal And
Prong
7
Black And White Input
Conductors
8
Green Or Green/Yellow
Ground Conductor
!
Always connect green or
green/yellow wire to ground
terminal, never to a load
terminal. Connect black (L1)
and white (L2) wires to load
terminals.
Ref. 120 813-D / Ref. 805 325-A