Sanyo VPC-E60 Service Manual page 19

Hide thumbs Also See for VPC-E60:
Table of Contents

Advertisement

Preparation:
Setting of pattern box:
Color temperature: 3100 ± 20 (K)
Luminance: 900 ± 20 (cd/m
Adjusting method:
1. Set the camera 0 cm from the pattern box. (Do not enter
any light.)
2. Double-click on the DscCalDi.exe.
3. Select "CCD Black" on the LCD "Test", and click the "Yes".
4. After the adjustment is completed, the number of defect
will appear.
3-8. Factory Code Setting
1. Check the "Factory Code" display within the Setting group.
2. For U.S.A., Canada and NTSC general area
If "FC_SANYO_U" does not appear, click on the "
located on the right of the "Factory Code" display BOX and
select "FC_SANYO_U".
3. For Europe and PAL general area
If "FC_SANYO_EX" does not appear, click on the "
located on the right of the "Factory Code" display BOX and
select "FC_SANYO_EX".
3-9. Language Setting
1. Click on the "
" mark located on the right of the
"Language" display BOX.
2. Select language. (Default is English.)
3. End "DscCal" and remove the camera before turning the
camera power OFF.
Calibration
Upload
LCD
RGB Odd
AWB
Firmware
Focus
RGB Gain
Data
UV Matrix
Tint
Cal Mode
PAF Cal.
OK
EVF
VCO
H AFC
Cal Data
LCD Type
OK
USB storage
VID
Get
Set
Serial
Set
PID
Backrush pulse :
Get
3-10. Reset Setting
Carry out reset settings after replacing CP1 board.
1. Turn on the camera.
2. Press the MENU button.
3. Choose the OPTION.
4. Choose the RESET SETTINGS, and press the SET
button.
5. Select Yes, and press the SET button.
3-11. The Compulsive boot starting method
1. Keep MENU button, SET button, and SHUTTER button de-
pressed while switching on the power.
2. Connect the camera and the computer with USB cable.
2
)
" mark
" mark
RGB Even
VCOMPP(LOW)
VCOMDC
VCOMPP(HI)
Phase
Hall Cal.
Test
Setting
Language
Set
Video Mode
Set
Rev.
Set
Factory Code
Set
3-12. Firmware uploading procedure
1. Uploading the firmware should be carried out if the version
number (COMPL PWB XX-X) on the replacement circuit
board is lower than the version of the distributed firmware.
For XX-X, enter the name of the circuit board containing the
firmware.
2. The firmware is distributed by e-mail in self-extracting archive
format. Change the extension of the distributed file to .EXE
and save it in your preferred folder.
3. When you double-click the saved file, the firmware (binary
file) will be saved in the same folder.
4. The firmware must not be distributed without permission.
1. Overwriting firmware from the SD card
Preparation:
SD card: SD card with firmware rewritten into the root direc-
tory
Data: S816Nxxx.BIN (xxx: version)
Overwriting method:
1. Insert the above SD card.
2. Turn on the camera.
3. Press the PLAY button.
4. Press the MENU button. The playback setting screen ap-
pears.
5. Choose the OPTION icon.
6. Choose the FORMAT.
7. Toggle the SET button to the left for 2 seconds. FIRMWARE
UPDATE will display.
8. Choose YES.
9. Press the SET button. Update is starting.
Note:
Do not turn off the camera's power or remove the SD card
while the firmware is being updated.
The power will turn on automatically after the update is com-
plete.
2. Overwriting firmware from the calibration software
Preparation:
PC with overwriting firmware copied to the preferred folder in
the HD.
Data: S816Nxxx.BIN (xxx: version)
Overwriting method:
1. Connect the camera's USB/AV terminal to the computer'
USB connector.
2. The USB Connection screen appears on the camera's LCD
monitor. Choose the "CARD READER", and press the SET
button.
3. Double-click on the DscCalDi.exe.
4. Click the Firmware.
5. Choose the fimware file to use for overwriting, and click
the Yes.
5. Update is starting. The message will appear, and choose
OK.
6. After the update is complete, disconnect the USB cable
and turn the camera's power off.
Note:
Do not turn off the camera's power while the firmware is be-
ing updated.