Assembly of clusters using the CP-XY15DF1 Dual Enclosure Flying Plate set

Attachment of wall mount brackets

! Four holes (M8) for wall mount brackets are provided on the rear of the XY-152.
! Hole layout (pitch): 127 mm × 70 mm (5 in. × 2.8 in.)
! Be sure to use wall mount brackets that have enough strength to be able to withstand the weight of the XY-152.

To rotate the HF waveguide

1
Using a 4 mm Allen key, unscrew the six M6 screws in the top and bottom of the enclosure (3 at each end). Gently remove the grille from the front of the enclosure.
2
Using a 4 mm Allen key, remove the eight countersunk bolts holding the HF waveguide in place.
3
Lift the waveguide up and rotate to the desired position.
4
Reinstate the socket-head bolts and retighten. Avoid over-tightening as this may crack the waveguide.
5
Reinstate the grille by gently placing it in place over the front of the loudspeaker. Replace the six M6 screws to secure it in place.
Using the supplied M10 socket head bolts, bolt through the CP-XY15DF1 plate into
the enclosures. Ensure that both the flat and spring washers are used — the flat
washer should be in contact with the plate. Once the desired angles of the loud-
speakers are set, tighten the bolts to lock in place. Then turn the cluster over and
repeat the process on the bottom. Use the top points on the XY-152 enclosures as a
secondary safety feature.