Glas Craft GCP2RA User Manual page 17

Probler p2 dispense gun
Table of Contents

Advertisement

Daily Shut-Down
For experienced users
Once you have used the gun with a product and system,
and you have become comfortable with techniques on
how all the variables are affecting your operations and
maintenance requirements, Daily, Weekly, and Monthly
maintenance requirements can be addressed specific to
your operation.
1.
Turn the ball valves off, activate and deactivate the gun
5 - 6 times to purge residual pressure.
2.
Engage piston lock.
3.
Drill out the chamber insert snout with correct size drill
bit for insert (see drill chart).
4.
Pull slide valve halfway back to limit the air purge.
Air Switch
Section 3 - General Information: Maintenance
ti19825a
ti21611a
5.
Use grease gun (Part No. 117792) to inject white lithium
grease (Part No. 117773) into zerk fitting until a light
mist of grease is purged through the snout. Shut off the
air purge.
Zerk Fitting
6.
Remove the air cap and set to side. If solvent soaking
is required, remove the o-ring before soaking.
7.
Remove the snout insert and soak in solvent until next
usage.
Insert
Air Cap
O-ring
Daily Start-Up
8.
Clean the snout insert. Be sure both, the face and bot-
tom flat are clean. Drill the snout bore out with the cor-
rect size bit for snout (see drill chart).
9.
Clean the inner bore of the chamber. Drill out the cham-
ber snout inlet bore as required.
10.
Install the snout insert.
11.
Install the air cap on to the chamber. Tighten finger
tight until the cap bottoms out. Snug down with a ½
in. wrench. This does not require high torque. Over
tightening can result in chamber damage.
17
ti21611a
ti21613a