GlasCraft Equipment
Air Hose is ¼ in. NPS
JIC and SAE Fittings DO NOT require the use of PTFE
tape.
Once the fittings are attached and tight, refer to system
manuals for start-up instructions.
ISO
*AIR
POLY
*Fitting GC2394 is an unattached part that may need to be
connected to the air hose first, depending on air hose fitting,
then connected to the gun.
Section 1 - Installation: Equipment Assembly
ti21609a
Installing P2 on Other Equipment
WARNING
Do not place any part of the body in the path of the
material spray. Do not point the gun at or near other
personnel. Do not look into the mixing chamber ori-
fice at any time. Because of the hazardous materials
used in this equipment, it is recommended that the
operator use an air mask, goggles, protective cloth-
ing, and other safety equipment as prescribed by
current regulations, recommendations of the chemi-
cal suppliers, and the laws in the area where the
equipment is being used.
If original equipment does not require the use of an un-
heated whip hose or isolation hose, the P2 can be directly
installed on to the material hose.
1.
Remove the fittings from the original gun.
2.
Remove swivel fittings from ball valves. Ball valves
are 1/8 in. NPT female. Remove swivel fitting from
air slide valve. The air slide valve is a ¼ in. NPSM.
3.
Install the original fittings into ball valves.
It is recommended to use a non-permanent thread
lock on the 1/8 in. NPT threads to assist as a sealant
and keep the fittings from twisting with gun move-
ment.
4.
Install the gun on the original hoses.
WARNING
Relieve ALL system fluid and air pressure according
to manufacturer's instructions.
10
ti21610a