Wiring
• To avoid an electric shock, prior to connecting the GLC's power cord
terminals to the power terminal block, confirm that the GLC's power
supply is completely turned OFF, via a breaker, or similar unit.
• The GLC2300-LG41-24V/GLC2300-TC41-24V units are designed
to use only DC24V input. Any other power level can damage both
the GLC and the power supply.
• Since there is no power switch on the GLC unit, be sure to attach
a breaker type switch to its power cord.
• When the FG terminal is connected, be sure the wire is grounded.
• To avoid a short caused by loose ring terminals, be sure to use ring
terminals with an insulating sleeve.
• When the FG terminal is connected, be sure the wire is grounded. Not
grounding the GLC unit will result in excess noise and vibration.
• The SG and FG terminals are connected internally in the GLC unit.
• When connecting the SG line to another device, be sure that the de-
sign of the system/connection does not produce a shorting loop.
• Wherever possible, use thick wires (max. 2 mm
twist the wire ends before attaching the ring terminals.
• Be sure to use the following size ring terminals.
Ring Terminals*
Connecting the GLC Power Cord
When connecting the power cord, be sure to follow the procedures given
below.
1. Confirm that the GLC's Power Cord is unplugged from the power supply.
2. Use a screwdriver to remove the Power Input Terminal Block's clear plastic
cover.
3. Unscrew the screws from the middle three (3) terminals, align the Ring
Terminals and re-attach the screws.
4. Replace the Power Input Terminal Block's clear plastic cover.
• Confirm that the ring wires are connected correctly.
• The torque required to tighten these screws is 0.5 to 0.6 N•m.
*1
Suggested Ring Terminal :
WARNINGS
1
Power Input
Terminal Block
V2-MS3 (made by JST)
-27-
*1
2
) for power terminals, and
Rear of GLC