Download Print this page

Error Codes - Glen Dimplex Combi 24 User Operating Instructions Manual

Combination condensing boilers
Hide thumbs Also See for Combi 24:

Advertisement

4.0

ERROR CODES

ERROR CODE
DESCRIPTION
1
Overheated
appliance
4
No flame
5
Flame loss
6
Temporarily
overheated appliance
7
Overheated appliance
11
Flame simulation
41
Water flow failure/
Flame for a short
period only
42
Water flow failure/
Flame for a short
period only
The boiler is in an ERROR state when there is an error code flashing on the back lit display.
CH = C C entral Heating
DHW = Domestic Hot Water
Press and release the RESET b b utton, the control tries to initiate a restart if possible
REASON
ACTION
CH Water temperature
•Check no air is in heat exchanger/CH system
greater than 105°C
•Check plate heat exchanger for blockages
•Check CH thermistor
•Check system bypass is functional
No flame signal on ignition
•Check detection electrode/lead – electrode may require cleaning
•Check spark gap
•Check gas supply & pressure
•Check flue system is connected properly
•Check condensate trap not blocked
•Check gas valve and/or lead
Loss of flame signal
•Check detection electrode/lead
during operation
•Check gas valve mains lead
Water temperature
•Check overheat thermostat
greater than 95°C
•Check no air is in heat exchanger/CH system
•CH system and hot water plate heat exchanger blockage
•Check CH thermistor
•Check system bypass is functional
Flue over temperature
•Check no air in heat exchanger
> 92°C
•Check flue thermistor
•Check flue system
•Check pump
•Check PCB/X8 connector
Flame detected when
•Check detection electrode/lead electrode may require cleaning
gas valve closed
•Check gas valve operation.
Low water pressure
•Check CH flow circulation
Reversed sensors
•Check water pressure(> 0.5 bar)
•Check pump/lead
•Check expansion vessel
•Check flow and return sensors connected correct way around
Low water pressure
•Check no air in heat exchanger
No flow
•Check CH flow circulation
Dry run protection
•Check water pressure(> 0.5 bar)
•Check pump/lead
•Check expansion vessel
BCC = Boiler Chip Card
RESET PO O SSIBLE
Y
Y
Y
Auto Re-start after 1 minute
Y
Y
Y
Y