8 8 Registering the settings from steps 3 3 to 7 7 into memory

The mode and setting numbers (1)(2) will start to flash when the MODE button E is pressed and registration will begin. The
numbers are set when the flashing stays lit.
WIf [---] appears in the room temperature display as the mode/setting number, or if a flashing [88] display appears, a transmis-
sion problem may have occurred. Check to see if there are some sources of transmission interference (noise) nearby.

9 9 Registering other settings simultaneously

Repeat steps 3 to 8 to make other function settings.
0 Completing the function settings
0
Press A FILTER and B TEST RUN buttons simultaneously for at least two seconds. (For modes 15 and higher, press J and
B simultaneously for at least 2 seconds.) After a while, the function selection screen will disappear and air conditioner OFF
display will appear.
FUNCTION
1
2
WDo not use the remote controller for 30 seconds after completing the function
setting. (Any requests will be rejected.)
FUNCTION
Note
Make sure to check all settings with
you have changed the settings of indoor units by this procedure after installa-
tion construction.
1
2
and etc. on the checklist of table 1 if
64