2-4. PICTURE TUBE REMOVAL

10
Four screws
(Tapping screw 5)
1 Anode cap
15
Two degaussing
coil holders
• REMOVAL OF ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT,
after removing the anode.
• REMOVING PROCEDURES
a
1
Turn up one side of the rubber cap in
the direction indicated by the arrow a.
• HOW TO HANDLE AN ANODE-CAP
1
Don't hurt the surface of anode-caps with shartp shaped material!
2
Don't press the rubber hardly not to hurt inside of anode-caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don't turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or hurt the rubber.
12
Demagnetic coil
2 A board
GND
GND
CN308
8
Neck assy
9
Deflection yoke
11
Picture tube
b
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow b.
13 Tension spring
5
CN603
GND
GND
CN307
CN506
CN501
14
Two
degaussing
coil holders
Connector
(2pin)
6 Claw
7
Bottom cover
(D board)
Cushion
3
2-2
CPD-110GS/110EST
Two screws
(+BVTP 4 x 16)
4
Stand assy
3 Claw
Anode Button
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling up it in
the direction of the arrow c.
c