Page 1
BHC501-506 – Dated 12th January 2011 CARRON CAST IRON STOVE INSTALLATION AND OPERATING INSTRUCTIONS Carron stoves are imported and distributed in the UK by: JIG UK Ltd, Hurlingham Business Park, Fulbeck Heath, A qualified solid fuel engineer must carry out the installation of this stove.
Page 2
12 Pa Flue gas mass flow 3.5 g/s EN13240:2001 Weight of Stove 55.0 Kg THE CARRON STOVE Minimum distance to combustible materials: Behind the stove: 550mm To the side of the stove: 450mm CO at 13% 02: 0.63% Flue gas temperature: 303ºC Efficiency:76.0%...
Page 3
Operating Instructions too low or cool, suitable kindling must be used to relight fires. Fuels suitable for use in your Carron Stove: - Wood – logs (no larger than 225mmx75mmx75mm) should be dried for at least a year Do not fuel the stove to a level higher than the bricks. The maximum amount of fuel prior to burning, for other fuels please contact the manufacturer.
Page 4
Controlling the stove - Setting the primary air supply (the inlet below the glass door) Carron stoves do not contain asbestos. However, please take care not to disturb any air control – sliding the air control to the right will allow the maximum amount of air into existing asbestos when removing an old stove.