Carrier AQUASNAP JUNIOR 30RA Installation Manual page 2

Aquasnap junior series
Hide thumbs Also See for AQUASNAP JUNIOR 30RA:
Table of Contents

Advertisement

30RA/30RH Puron
Water chillers, air-cooled with integrated hydronic section
For operation and maintenance instructions of this unit as well as installation
instructions of the indoor unit, refer to the relevant manuals.
Contents
Dimensions and weight .................................................................................................................
Technical data ................................................................................................................................
Minimum clearances ......................................................................................................................
Electrical data ................................................................................................................................
Data ...............................................................................................................................................
General information .......................................................................................................................
Warnings: avoid .............................................................................................................................
Water connections .........................................................................................................................
Connections and water circuits .....................................................................................................
Electrical connections ....................................................................................................................
Water-refrigerant heat exchanger .................................................................................................
Check the refrigerant charge .........................................................................................................
Unit maintenance ...........................................................................................................................
Control and safety devices ............................................................................................................
Diagnostics ....................................................................................................................................
Troubleshooting and guide for the owner ......................................................................................
Accessories ...................................................................................................................................
ATTENTION INSTALLERS AND SERVICE TECHNICIANS!
AIR CONDITIONER WITH R-410A REFRIGERANT
• R-410A refrigerant operates at 50%-70% higher pressures than R-22. Be sure that servicing
equipment and replacement components are designed to operate with R-410A.
• R-410A refrigerant cylinders are pink in colour.
• R-410A refrigerant cylinders have a dip tube which allows liquid to flow out of the cylinder in upright
position.
• The R-410A units must be charged with refrigerant in a liquid state. Use a commercial type metering
device in the manifold hose in order to vaporize the liquid refrigerant before it enters in the unit.
• R-410A, as other HFCs, is only compatible with the following oils selected by the compressor
manufacturer.
• The vacuum pump is not sufficient to remove moisture from the oil.
• POE oils absorb moisture rapidly. Do not expose oil to atmosphere.
• Never open unit to atmosphere while it is under a vacuum.
• When unit must be opened for service, break vacuum with dry nitrogen and replace filter dryer.
• Do not vent R-410A into the atmosphere.
Unit size
005 - 007
009 - 011
013
Table I
Cooling only models
30RA005---7
30RA007---7
30RA007---9
30RA009---9
30RA011---7
30RA011---9
30RA013---9
Quantity
Oil type
POE
1.12
POE
1.25
POE
1.95
Heat pump models
30RH005---7
30RH007---7
30RH007---9
30RH009---9
30RH011---7
30RH011---9
30RH013---9
Drier already installed on
l
liquid line of the unit
230 V ~ 50 Hz
230 V ~ 50 Hz
400 V 3N~ 50 Hz
400 V 3N~ 50 Hz
400 V 3N~ 50 Hz
400 V 3N~ 50 Hz
Pagina
2
2
3
3
4
5
6
7
8/9
10/12
12/13
14
14
14
15
16
16
YES
YES
YES
Power supply
230 V ~ 50 Hz
GB - 1