Pa-
Name
rame-
ter
No.
n52
DC control cur-
rent
n53
Interruption DC
control time
n54
Startup DC con-
trol time
n55
Stall prevention
during decelera-
tion
n56
Stall prevention
level during ac-
celeration
n57
Stall prevention
level during op-
eration
n58
Frequency detec-
tion level
n59
Overtorque
detection function
selection
n60
Overtorque
detection level
n61
Overtorque
detection time
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Description
Used to impose DC on the induction motor
for braking control.
Set the DC braking current in percentage
g
based on the rated current of the Inverter
based on the rated c rrent of the In erter
as 100%.
Output
frequency
frequency
Minimum
output
frequency
(n14)
n54
Used to select a function to change the de-
celeration time of the motor automatically
so that there will be no overvoltage im-
posed on the motor during deceleration.
0: Stall prevention during deceleration en-
abled
1: Stall prevention during deceleration dis-
abled
Used to select a function to stop the accel-
eration of the motor automatically for stall
prevention during acceleration.
Set the level in percentage based on the
rated current of the Inverter as 100%.
Used to select a function to reduce the out-
put frequency of the Inverter automatically
for stall prevention during operation.
Set the level in percentage based on the
rated current of the Inverter as 100%.
Used to set the frequency to be detected.
Note The parameter n40 for multi-function
output must be set for the output of
frequency detection levels 1 and 2.
Used to enable or disable overtorque
detection and select the processing meth-
od after overtorque detection.
0: Overtorque detection disabled
1: Overtorque detection only when speed
coincides and operation continues (is-
sues alarm)
2: Overtorque detection only when speed
coincides and output shut off (for protec-
tion)
3: Overtorque always detected and opera-
tion continues (issues alarm)
4: Overtorque always detected and output
shut off (for protection)
Used to set overtorque detection level.
Set the level in percentage based on the
rated current of the Inverter as 100%.
Used to set the detection time of overtor-
que.
Set-
Unit
Default
setting
ting
of set-
range
ting
0 to
1%
50
100
g
0.0 to
0.1 s
0.0
25.5
0.0 to
0.1 s
0.0
25.5
Time
n53
0, 1
1
0
30 to
1%
170
200
30 to
1%
160
200
0.0 to
0.1 Hz
0.0
400
0 to 4
1
0
30 to
1%
160
200
0.1 to
0.1 s
0.1
10.0
Chapter 9
Changes
Refer-
during
ence
opera-
page
tion
No
6-5
No
6-5
No
6-5
No
6-6
No
6-7
No
6-8
No
6-18
No
6-9
No
6-9
No
6-10
9-11