Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RJ040F2HXEB and is the answer not in the manual?

Questions and answers

Summary of Contents for Samsung RJ040F2HXEB

  • Page 2: Table Of Contents

     This manual explains how to install an indoor unit with a split system with two SAMSUNG units. The use of other types of units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.
  • Page 3  In order to prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.
  • Page 4: Deciding On Where To Install The Air Conditioner

    Deciding on Where to Install the Air Conditioner When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account. General Do NOT install the air conditioner in a location where it will come into contact with the following elements: ◆...
  • Page 5 ◆ RJ040F2HX ** ◆ Piping outside diameter Indoor unit Outdoor unit Power supply 0, V, Hz Outside diameter Unit Liquid ** 020/023/026/035 RJ040F2HX ** 1,220-240,50/60 07/09/12 ** ** 020/023/026/035 1/4" 3/8" 07/09/12 ** ※ RJ040F2HX ** Outdoor unit cannot be connected to the following indoor unit combination. - ** 052 ** /MH *** FM * A/NJ *** LHXEA/ ** 18 ** / ** 24 ** 200 mm or more...
  • Page 6 Deciding on Where to Install the Air Conditioner ◆ RJ050F2HX ** ◆ Piping outside diameter Indoor unit Outdoor unit Power supply 0, V, Hz Outside diameter Unit Liquid ** 020/023/026/ 035/052 RJ050F2HX ** 1,220-240,50/60 ** 020/023/026/ 3/8" 07/09/12/18 ** 030/035/07/09/12 ** 1/4"...
  • Page 7 ◆ RJ060F3HX ** ◆ Piping outside diameter Indoor unit Outdoor unit Power supply 0, V, Hz Outside diameter Unit Liquid ** 020/023/026/ 030/035/052 RJ060F3HX ** 1,220-240,50/60 ** 020/023/026/ 3/8" 07/09/12/18 ** 030/035/07/09/12 ** 1/4" ** 052/18 ** 1/2" 200 mm or more 100 mm 160 mm or more or more...
  • Page 8 Deciding on Where to Install the Air Conditioner ◆ RJ070/080F4HX ** ◆ Piping outside diameter Indoor unit Outdoor unit Power supply 0, V, Hz Outside diameter Unit Liquid ** 020/023/026/ RJ070F4HX ** 030/035/052/ 1,220-240,50/60 ** 020/023/026/ 3/8" RJ080F4HX ** 07/09/12/18/24 ** 030/035/07/09/12 ** 1/4"...
  • Page 9: When Installing 1 Outdoor Unit

    Space Requirements for Outdoor Uni When installing 1 outdoor unit (Unit : mm) ※ When the air outlet is opposite the wall ※ When the air outlet is towards the wall 2000 or more 300 or more 600 or more ※...
  • Page 10 Deciding on Where to Install the Air Conditioner When installing more than 1 outdoor unit (Unit : mm) 300 or more 600 or more 600 or more 600 or more ※ When 3 sides of the outdoor unit are blocked by the wall 600 or more 600 or more ※...
  • Page 11: Air Conditioner And Accessories

    A A ir conditioner and accessories The following accessories are supplied with the air conditioner. Accessories in the Outdoor Unit Case ◆ RJ040F2HX ** /RJ050F2HX ** /RJ060F3HX ** Flare Bolt 3-wire 2-wire Flare Nuts, 9.52mm (Nut 12.70mm;Bolt Installation Power Cable Assembly Cable Drain Plug Energy Label...
  • Page 12: Cutting/Extending The Piping

    A C utting/extending the piping 1. Make sure that you have the required tools available (pipe cutter, reamer,flaring tool and pipe holder). 2. If you wish to shorten the piping, cut it using a pipe cutter, taking care toensure that the cut edge remains at a 90° angle with the side of the pipe,and referring to the illustrations below for examples of edges cut correctlyand incorrectly.
  • Page 13 Connecting the cables to the outdoor unit ◆ RJ040F2HX ** /RJ050F2HX ** A-unit B-unit Indoor unit 1(L) 2(N) 1(L) 2(N) F1 F2 F1 F2 Assembly cable Earth Earth terminal terminal F1 F2 F1 F2 Earth Earth terminal terminal Outdoor unit F1 F2 Main Power Supply cable...
  • Page 14 Connecting the cables to the outdoor unit ◆ RJ060F3HX ** B-unit C-unit A-unit Indoor unit 1(L) 2(N) 1(L) 2(N) 1(L) 2(N) Assembly cable F1 F2 F1 F2 F1 F2 Earth Earth Earth terminal terminal terminal F1 F2 F1 F2 F1 F2 Earth Earth Earth...
  • Page 15 ◆ RJ070F4HX ** /RJ080F4HX ** A-unit B-unit C-unit D-unit Indoor unit 1(L) 2(N) 1(L) 2(N) 1(L) 2(N) 1(L) 2(N) Assembly cable F1 F2 F1 F2 F1 F2 F1 F2 Earth Earth Earth Earth terminal terminal terminal terminal F1 F2 F1 F2 F1 F2 F1 F2 Earth...
  • Page 16: Transmitter Installation (Optional)

    A T ransmitter installation(optional) ◆ RJ040F2HX ** /RJ050F2HX **/RJ060F3HX**/RJ070F4HX**/RJ080F4HX** Accessories (Transmitter: MIM-B13A) DC Power Cable DC Power Cable Communication Transmitter Transmitter SUB Communication Cable Tie Case MAIN (12V) (5V) Cable Cable R2 R1 R2 R1 R2 R1 R2 R1 R2 R1 R2 R1 R2 R1 R2 R1 R2 R1 R2 R1 R2 R1 R2 R1...
  • Page 17 DC 12V (Blue) (Blue) DC 12V supply R1 R2 CN01(Blue) DC 12V (Blue) RJ060F3HX ** /RJ070F4HX ** /RJ080F4HX ** RJ-040F2HX ** /RJ050F2HX ** Transmitter MAIN PCB Outdoor unit PCB 1(L) 2(N) 1(L) 2(N) Terminal Block in Terminal Block in the outdoor unit the outdoor unit RJ060F3HX**/RJ070F4HX**/RJ080F4HX ** RJ040F2HX ** /RJ050F2HX **...
  • Page 18: Checking Correct Earthing

    A C hecking correct earthing If the power distribution circuit does not have an earth or the earth does not comply with specifications, an earthing electrode must be installed. The corresponding accessories are not supplied with the air conditioner. Select an earthing electrode that complies with the specifications Carbon given in the illustration opposite.
  • Page 19: Connecting Up And Purging The Circuit

    A C onnecting up and purging the circuit WARNING When installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor first before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high.
  • Page 20: Adding Refrigerant

    A C onnecting up and purging the circuit ◆ RJ060F3HX ** /RJ070F4HX ** /RJ080F4HX ** 1 Check the piping connections. 2 Connect the charging hose of low pressure side of manifold gauge to the packed valve having a service port (5/8” Packed valve) as shown at the figure (Value stem: 1/2”...
  • Page 21: Performing Leak Tests

    Adding refrigerant Important information regulation regarding the refrigerant used This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. CAUTION : Refrigerant type GWP value Inform user if system contains 3 kg or more of fluorinated greenhouse gases. R410A 1975 In this case, it has to be checked for leakage at least once every 12 months,...
  • Page 22: Pipe Installation With Indoor Units

    Performing leak tests RJ040F2HX ** / RJ050F2HX ** PUMP DOWN (before disconnecing t the refrigerant connections for unit repair, removal or disposal) Pump-down is an operation intended to collect all the system refrigerant in the outdoor unit. This operation must be carried out before disconnecting the refrigerant pipe in order to avoid refrigerant loss to the atmosphere.
  • Page 23: Setting An Indoor Unit Address And Installation Option

    A S etting an indoor unit address and installation option RJ040F2HX ** /RJ050F2HX ** CAUTION This product is prohibited one indoor unit installation. Don't use pipe checking operation and Auto Addressing Mode when one indoor unit is installed.  SW0 2 ◆ Switch the system on and wait for code " "...
  • Page 24 A S etting an indoor unit address and installation option Review all the following elements in the installation: Step 1 ◆ Installation site strength ◆ Piping connection tightness to detect any gas leakage ◆ Connection wiring ◆ Heat-resistant insulation of the piping ◆...
  • Page 25 TO SET ADDRESSING MANUALLY BY TYPE PICTURE MODEL ROTARY SWITCH “SW02” Same for: IT'S HERE! SERIE VISION SERIE VISION MH020FV(N/A)** MH023FB** MH026FB(V/N/A)** MAIN MH035FB(V/N/A)** MH052FB(V/N/A)** MH026FS** SLIM 1 WAY MH035FS** MH030FM** MINI 4 WAY MH035FM** MH052FM** MH026FE** MH035FE** SLIM DUCT NJ026LHX** MSP-DUCT NJ035LHX**...
  • Page 26 Setting an indoor unit address and installation option ROTARY SWITCH “SW02” POSITION ACCORDING TO REFRIGERANT CIRCUIT CONNECTED ( 0=A; 1=B; 2=C; 3=D ) Indoor Unit Indoor Unit OUTDOOR UNIT OUTDOOR UNIT SW02 SW02 Att. "A" Att. "A" A unit Att. "B" Att.
  • Page 27 Setting Option (AQV07/09/12/18/24****) Entering mode for Option setting option setting mode Mode change High Temp Button High Fan Button Low Temp Button Low Fan Button Indoor unit Model Option NO. AQV07PSBN 011305-1740E9-271416-372500-03403D-112E3F AQV09PSBN 011305-17421D-271921-372500-03403D-112E3F MALDIVES AQV12PSBN 011305-17423D-272328-372500-034B46-11474D AQV18PSBN 012305-17421D-27323C-372600-034743-113F47 AQV24PSBN 012305-17427B-27444E-378200-034C4B-104442 AQV09YWAN 010345-17C0F5-271920-372500-033B32-102A3C JUNGFRAU...
  • Page 28 Setting an indoor unit address and installation option The procedure of setting option Operation Indication * Step 1 1. Remove the batteries from the remote controller. 2. Insert batteries while pressing High Temp Button and Low Temp Button. * Step 2 1.
  • Page 29 Setting an indoor unit address (MAIN/RMC) 1. Check whether power is supplied or not. - When the indoor unit is not plugged in, there should be additional power Indoor Unit supply in the indoor unit. 1(L) 2. The panel(display ) should be connected to an indoor unit to receive option. 2(N) 3.
  • Page 30 Setting an indoor unit address and installation option •  W hen“A”~”F”isenteredtoSEG4~6,theindoorunitMAINADDRESSisnotchanged. •  I fyousettheSEG3as0,theindoorunitwillmaintainthepreviousMAINADDRESSevenifyouinputtheoptionvalueofSEG4~6. •  I fyousettheSEG9as0,theindoorunitwillmaintainpreviousRMCADDRESSevenifyouinputtheoptionvalueofSEG11~12. 5. The MAIN address is for commnication between the indoor unit and the outdoor unit. Therefore, you must set it to operate the air conditioner properly.
  • Page 31 It could take maximum 60 minutes to operate for the protection of the compressor. if the outdoor temperature is below -5°C. Ampere Limit Setting & Changing Procedure WARNING ◆ Do not adjust the “Ampere Limit Switch”, if it’ s not necessary : before modifying it, evaluate the total number of electric and electronics loads consumption and use “Ampere limits switch”...
  • Page 32 A S etting an indoor unit address and installation option Settings of PCB Display of the Outdoor unit ◆ Key Options of PCB Display - K1 : pipe checking operation button - K2 : Function button - K3 : Reset button - K4 : View mode change button RJ040F2HX ** /RJ050F2HX ** Push...
  • Page 33: Troubleshooting

    A T roubleshooting The table below give indication about self diagnostic routine. Some of error code requires activities exclusively for Authorise Service Center. The error indicated on the PCB display of outdoor unit EXPLANATION (The error indicated on the PCB display of outdoor unit) DISPLAY REMARK Communiaction error(indoor unable to receive data)
  • Page 34 Troubleshooting The table below give indication about self diagnostic routine. Some of error code requires activities exclusively for Authorise Service Center. The error indicated on the PCB display of outdoor unit DISPLAY EXPLANATION (The error indicated on the PCB display of outdoor unit) REMARK EvaOut2 Sensor Short/Open EvaOut3 Sensor Short/Open...
  • Page 35: Explaining Operations To The Owner

    Explaining operations to the owner Before leaving the premises on which you have installed the air conditioner, you should explain the following operations to the owner, making reference to the appropriate pages in the owner’s instruction booklet. 1. How to start and stop the air conditioner. 2.
  • Page 36 "EEE Yönetmeliğine Uygundur" "This EEE is compliant with RoHS"...
  • Page 37: Air Conditioner

    RJ040F2HX RJ050F2HX RJ060F3HX RJ070F4HX RJ080F4HX Air Conditioner installation manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register F I P D G DB98-33017A(1)

Table of Contents

Save PDF