Terminal Description (continued)
C
Parameters used for the data format
The following 3 types of parameters are used for command and response data:
(1) Numeric value
Each parameter is as follows:
(1) Numeric value
A 2-byte hexadecimal value (sign included) is represented by a set of 4-digit (4-byte) characters.
The range that can be specified is from 8000H to 7FFFH
(2) ON/OFF
Shows the status (ON or OFF) of the unit, such as POWER and HIDE.
Character
0
1
(3) Special parameters
Operation mode parameters
Character
0000
0001
0002
0004
c
External control command table
Function
Operate
HIDE
Left/Right Reversal
Top/Bottom
Inversion
Operation Mode
Operation mode: Only Asking command is possible
46
(2) ON/OFF
(3) Special parameters
Hex
Meaning
30
OFF
31
ON
Hex
30h 30h 30h 30h
Standby mode
30h 30h 30h 31h
Operate mode
30h 30h 30h 32h
Cool down mode
30h 30h 30h 34h
Emergency mode
Asking
Command
Operate mode
U0F
X
U00
X
U17
X
U18
X
Z03
Meaning
ELSE
Numeric Value
X
Data Type
ON/OFF
Special Data
X
X
X
X
X