Toshiba RAS-10N3AV2-A Service Manual page 33

Split type
Table of Contents

Advertisement

Item
2. Indoor fan
<In cooling operation>
motor control
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
COOL ON
Fan speed setup
AUTO
Ta
[ ˚C ]
+2.5
a
+2.0
b
+1.5
c
+1.0
d
+0.5
e
Tsc
(Table 1) Indoor fan air flow rate
Fan speed
level
COOL HEAT DRY
WF
UH
WE
H
UH
WD
UH
M+
WC
H
H
M
M+
WB
M+
WA
M
W9
M
L+
W8
L
W7
L+
L-
L+
W6
L
L
W5
L-
UL
L-
W4
UL
UL
W3
SUL
SUL
W2
SUL
W1
Operation flow and applicable data, etc.
MANUAL
Indication
L
L+
M
M+
H
Air volume AUTO
M+(WB)
*3
*3 : Fan speed = (M + –L) x 3/4 + L
*4
*4 : Fan speed = (M + –L) x 2/4 + L
*5
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
L(W6)
from M+ and L)
RAS-10N3KV2-A
RAS-13N3KV2-A
Fan speed
Air flow rate
Fan speed
(rpm)
(m3/h)
(rpm)
1210
571
1300
1210
571
1300
1170
546
1300
1120
515
1300
1040
465
1150
1100
1000
440
1050
960
415
920
870
359
870
850
347
820
760
291
760
291
770
700
253
720
650
222
670
500
129
520
500
129
500
* The values of fan speed and air flow
(Fig. 1)
Fan speed
W6
1) When setting the fan speed to L,
(L + M) / 2
W9
(M + H) / 2
WC
2) When setting the fan speed to
(Fig. 2)
RAS-16N3KV2-A
Air flow rate Fan speed
Air flow rate
(m3/h)
(rpm)
(m3/h)
620
1510
735
620
1510
735
620
1480
717
620
1430
686
514
1280
594
495
1220
557
465
1150
514
372
1000
421
359
980
409
320
920
372
297
900
360
266
840
323
234
770
280
141
620
187
129
520
126
– 32 –
FILE NO. SVM-13001
Description
* Symbols
UH
: Ultra High
H
: High
M+
: Medium+
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
volume indicate on the table are
measured when the louver is inclined
downward. Fan speed and air flow
volume broadly vary with position
of louver.
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup temperature
and room temperature.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents