CITROEN 2001 BERLINGO Handbook page 174

Saxo-xsara
Table of Contents

Advertisement

ALL TYPES
(11) Evaporator control valve.
- make : NECAM.
- type : MEGA.
ESSENTIAL :
Before checking and setting the pressure, it is essential that you
read through and follow closely BROCHURE REF : 0332.
Setting pressure - 1st stage.
- Setting pressure for a new evaporator control valve :
1450 ± 50 mb.
- Setting pressure for a used evaporator control valve :
1400 ± 50 mb.
SPECIFICATIONS : PETROL/LPG DUAL FUEL SYSTEM
Setting pressure - 2nd stage.
- Setting pressure for a new evaporator control valve :
- 970 ± 10 mb.
- Setting pressure for a used evaporator control valve :
- 960 ± 10 mb.
(12) Stepper motor.
- location : on the distributor.
(13) Distributor.
- location : on the evaporator control valve support.
(14) Distributor electrovalve.
- supply voltage : 12 volts.
- resistance : 25 ohms.
170

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2001 saxo2001 xsara

Table of Contents