Fig. 2. Controls.
Central heating
demand indicator
Mains
electricity
indicator
0
I
Mains electricity
On/Off

INDICATOR LIGHTS

Mains electricity indicator:
Central heating demand indicator:
FLASHING SLOW : Ignition lockout
(once per second)
FLASHING FAST : Appliance fault (other than ignition
(five times per second)
Domestic hot water demand indicator:
FLASHING FAST : Air flow fault
(five times per second)
Central heating and domestic hot water demand indicators:
BOTH FLASHING SLOW : Overheat cut-off
(once per second)
Flame detection indicator:
DHW demand
indicator
Reset
button
!
CH temp
DHW temp
control knob
control knob
OFF : No mains electricity to the contol
board
ON : Mains electricity is connected to the
appliance
OFF : No demand for heat to the central
heating circuit
ON : Central heating or autofrost demand
lockout)
OFF : No demand for domestic hot water
ON : Domestic hot water demand
OFF : Burner off
ON : Burner on
Flame detection