Worcester C1 Installation And Servicing Instructions page 31

Wall mounted combination boiler for central heating and mains fed domestic hot water
Table of Contents

Advertisement

END DHW
DEMAND
seconds every 10
END CH
DEMAND
No demand
and primary
temperature
below 8°C
Internal
Run pump for
Run pump
"Autofrostat"
four minutes
demand
OVERRUN FUNCTION
Fan overrun
function active
for 3 minutes
If primary temp
over 85° pump
cycles for 2
seconds until
temp below
85°
Pump runs for
3 minutes
AUTOFROSTAT FUNCTION
Wait in normal
off state for
30 minutes
Monitor
central
heating
sensor
31
If primary temp
above 80° fan
runs until temp
below 80°C
(35 seconds
minimum)
If primary temp
below 80° run
fan for 35
seconds
After 3 minutes the pump runs if:
primary temp over 95° until below 77°
hot water temp over 98° until below 63°
5°C
Below
Above
to
5°C
9°C
9°C
Commence normal
central heating mode
until temperature
reaches 30°C
20°C
If primary rises
above 85° fan
runs until temp
falls below 80°
Return to
normal off
state