2. SPECIFICATIONS

2-1. Unit Specifications

Indoor Unit
KHS1872
Outdoor Unit
CH1872
Voltage Rating
Performance
Total Capacity
Sensible Capacity
Latent Capacity
Air Circulation (High)
Moisture Removal (High)
Electrical Rating
Available Voltage Range
Running Amperes
Power Input
Power Factor
SEER
HSPF
Compressor Locked Rotor Amperes
Fuse or Circuit Breaker Capacity
Features
Controls / Temperature Control
Control Unit
Timer
Fan Speeds
Airflow Direction (Indoor)
Air Filter
Compressor
Refrigerant / Amount charged at shipment
Refrigerant Control
Operation Sound
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Max. allowable tubing length at shipment
Refrigerant
Tube Diameter
Refrigerant Tube Kit / Accessories
Dimensions & Weight
Unit Dimensions
Height x Width x Depth
Package Dimensions
Height x Width x Depth
Weight
Shipping Volume
Remarks: Rating conditions are:
Cooling: Indoor air temperature
Outdoor air temperature 95°F D.B. / 75°F W.B.
Heating: Indoor air temperature
Outdoor air temperature 47°F D.B. / 43°F W.B.
3
ft
/min (m
Pints/h
BTU/W
BTU/W
Indoor / Outdoor
Horizontal
Vertical
Indoor : Hi/Me/Lo/Qt*
Outdoor : Hi
Narrow tube
inch (mm)
Wide tube
inch (mm)
Net
Shipping
cu.ft (m
80°F D.B. / 67°F W.B.
70°F D.B.
Cooling
BTU/h
17,500
( 4,000 to 17,500 )
kW
5.15
( 1.2 to 5.15 )
BTU/h
13,100
BTU/h
4,400
3
524 (890)
/h)
4.89
Cooling
V
A
7.0
( 1.2 to 7.0 )
W
1,500
( 250 to 1,500 )
%
93
16
-
A
A
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
24-Hour ON or OFF Timer, 1-Hour OFF Timer
Auto and 3 steps / Auto (Hi, Me, Lo)
lb. (g)
dB-A
42 / 38 / 30 / 28
dB-A
51
ft. (m)
Indoor Unit
inch
11-23/32 x 41-15/16 x 8-19/32
(mm)
(298 x 1,065 x 218)
inch
11-3/8 x 44-7/8 x 14-29/32
(mm)
(289 x 1,140 x 379)
lb. (kg)
26.5
(12.0)
lb. (kg)
33.1 (15.0)
3
4.23 (0.12)
)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
6
230V Single-Phase 60Hz
Heating
20,400
( 4,400 to 20,400 )
6.0
( 1.3 to 6.0 )
541 (920)
Heating
187 to 253
7.4
( 1.3 to 7.4 )
1,575
( 270 to 1,575 )
17.5
20
Manual
Auto
Washable, Anti-Mold
DC Twin Rotary (Inverter)
R410A / 2.87 (1,300)
Electric Expansion Valve
41 / 38 / 30 / 28
Flare Type
25 (7.5)
1/4 (6.35)
1/2 (12.7)
Optional / Air Clean Filter
Outdoor Unit
26-3/8 x 34-21/32 x 11-7/32
(670 x 880 x 285)
29-1/8 x 39-27/32 x 14-31/32
(740 x 1,012 x380)
97.0 (44.0)
105.8
9.88
<
>
230V
-
-
-
93
-
7.7
52
(48.0)
(0.28)