Kyocera FS-1350DN Service Manual page 42

Hide thumbs Also See for FS-1350DN:
Table of Contents

Advertisement

2H4
Code
2000
Main motor error
The main motor ready input is not given
for 2 s during the main motor is ON.
4000
Polygon motor (laser scanner unit)
error
The polygon motor ready input is not
given for 6 s during the polygon motor is
ON.
4200
BD error (laser scanner unit) error
6000
Broken fuser heater lamp wire
The fuser temperature does not rise after
the fuser heater lamp has been turned
on.
6020
Abnormally high fuser thermistor
temperature
Fuser thermistor detects abnormally
temperature.
1-4-4
Contents
Causes
Check procedures/corrective measures
Defective harness
Reinsert the connector. Also check for conti-
between main
nuity within the connector harness. If none,
motor (CN1) and
remedy or replace the harness.
control PWB
(YC305), or
improper connec-
tor insertion.
Defective drive
Check if the rollers and gears rotate
transmission sys-
smoothly. If not, grease the bushings and
tem of the main
gears. Check for broken gears and replace if
motor.
any.
Defective main
Replace the main motor (See page 1-5-28).
motor.
Defective control
Replace the control PWB (See page 1-5-
PWB.
19).
Defective harness
Reinsert the connector. Also check for conti-
between polygon
nuity within the connector harness. If none,
motor and control
remedy or replace the harness.
PWB (YC319), or
improper connec-
tor insertion.
Defective laser
Replace the laser scanner unit (See page 1-
scanner unit.
5-29).
Defective control
Replace the control PWB (See page 1-5-
PWB.
19).
Defective laser
Replace the laser scanner unit (See page 1-
scanner unit.
5-29).
Defective control
Replace the control PWB (See page 1-5-
PWB.
19).
Poor contact in the
Reinsert the connector (See page 1-5-16).
fuser thermistor
connector termi-
nals.
Poor contact in the
Reinsert the connector (See page 1-5-16).
fuser heater lamp
connector termi-
nals.
Fuser thermistor
Replace the fuser unit (See page 1-5-16).
installed incor-
rectly.
Fuser thermal cut-
Replace the fuser unit (See page 1-5-16).
out triggered.
Fuser heater lamp
Replace the fuser unit (See page 1-5-16).
installed incor-
rectly.
Broken fuser
Replace the fuser unit (See page 1-5-16).
heater lamp wire.
Shorted fuser ther-
Replace the fuser unit (See page 1-5-16).
mistor.
Defective control
Replace the control PWB (See page 1-5-
PWB.
19).
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents