• Installation and adjustment of the burner requires technical and
efficient knowledge and the use of combustion test instruments.
Do not tamper with the unit or controls. Call your qualified ser-
vice agency.
• Incorrect operation of the burner could result in severe personal
injury, death, or substantial property damage.
7.
Examine burner door for signs of deterioration.
8.
Examine the furnace as outlined above in steps 1 - 7 before each
heating season. Use Figure 2 for visual reference.
If, during the inspection of your furnace, you find any of the following
conditions:
• Excessive amounts of dust and lint on components.
• Damaged or deteriorated components or surfaces.
• Leaks or blockage in the vent pipe passages.
• Water on any surface inside or outside of the furnace.
Do not operate the furnace, call a certified dealer / servicing contractor
to check and / or clean your furnace, or for more information if you have
questions about the operation of your furnace.
If all components appear to be in good operating condition, replace the
front panels. Turn ON the oil and electrical power supplies to the fur-
nace, and set thermostat to the desired temperature.
2. Examine Filter Door
4. Examine Burner Door
5. Remove Burner
Door to Examine
Furnace Base and
Air Conditioning
Coil Panels
FIGURE 3: Furnace Examination Checkpoints

OWNER SERVICE AND MAINTENANCE

Properly installed and maintained, your AF burner will provide years of
efficient, trouble-free operation. Please take care of your equipment by
following the warnings provided and by doing the following (notify your
qualified service agency if you find anything wrong):
ANNUALLY
• Have your burner serviced annually by your qualified service
agency, as noted above.
• Refer to the appliance manufacturer's instructions for recom-
mended appliance servicing and cleaning interval.
Unitary Products Group
1. Examine Vent Pipe
3. Remove Filter
Door to Examine
Combustion Air Pipe
7. Remove Burner
Door to Examine
Burner Flame
DAILY
Check the room in which your burner / appliance is installed. Make
sure:
• Air ventilation openings are clean and unobstructed
• Nothing is blocking the burner inlet air openings
• No combustible materials are stored near the heating appliance,
and
• There are no signs of oil or water leakage around the burner or
appliance.
WEEKLY
• Check your oil tank level. Always keep your oil tank full, espe-
cially during the summer, in order to prevent condensation of
moisture on the inside surface of the tank.

START-UP AND SHUTDOWN INSTRUCTIONS

Read the Instructions Below Before Trying to Start the
Furnace
If you do not follow these instructions exactly, a fire or explo-
sion may result causing property damage, personal injury,
and/or loss of life.
1.
This appliance does not have a pilot. It is equipped with an ignition
device which automatically lights the burner. Do not try to light the
burner by hand.
2.
BEFORE OPERATING; smell all around the appliance area for
fuel oil. Be sure to smell next to the floor because fuel oil is heavier
than air and will settle on the base of the chamber. Look for any oil
leaks around the base of the furnace.
3.
Use only your hand to turn the manual oil line valve attached the
pump to the "on" position. Never use tools. If the valve will not
operate by hand, don't try to repair it, call a qualified service tech-
nician. Force or attempted repair may result in a fire or explosion.
4.
Do not use this appliance if any part has been under water. Imme-
diately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any oil burner
control, which has been under water.
Operating Instructions:
1.
STOP! Read the safety information above.
2.
Set the thermostat to the lowest setting.
3.
Turn off all electric power to the appliance.
4.
Remove burner door.
5.
Turn the valve on the oil pump to the closed position. Do not force.
6.
If you then smell fuel oil, STOP! Follow "B" in the safety informa-
tion above. If you don't smell fuel oil, go to next step.
7.
Turn the valve attached to the oil pump to the open position. Do
not force.
8.
Replace burner door.
9.
Turn on all electric power to the appliance.
10. Set thermostat to the desired setting. Burner will light, which may
take 10-15 seconds.
11. After one (1) trial for ignition, if the appliance will not operate follow
the instructions, "TO TURN OFF THE APPLIANCE" and call your
service technician or fuel supplier.
107273-UUM-C-0306