INSTALLATION MANUAL
TWO STAGE STANDARD ECM
RESIDENTIAL GAS FURNACES
MODELS: TM9Y Series
(96% AFUE Multi-position)
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
GAS PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
ELECTRICAL POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
TWINNING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
VENTING CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Duct Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Vertical Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Coil Cabinet Attachment Flanges . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Horizontal Right Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Horizontal Left Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
PC Series Upflow Coil Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Combustible Floor Base Accessory . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Horizontal Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Typical Attic Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Downflow Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Side Return Cutout Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Gas Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Electrical Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Two Stage Standard ECM Furnaces . . . . . . . . . . . . . . . . . . . . . . . . 13
Two Stage Standard ECM Furnace . . . . . . . . . . . . . . . . . . . . . . . . . 14
Typical. Condensate Drain, Vertical Installation . . . . . . . . . . . . . . . . 15
Unit Clearances to Combustibles . . . . . . . . . . . . . . . . . . . . . . . . 4
Coil Projection Dimensions - PC Series Coils . . . . . . . . . . . . . . . 7
Cabinet and Duct Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Nominal Manifold Pressure - High Fire . . . . . . . . . . . . . . . . . . . 11
Nominal Manifold Pressure - Low Fire . . . . . . . . . . . . . . . . . . . 11
Ratings & Physical / Electrical Data . . . . . . . . . . . . . . . . . . . . . 12
Maximum Equivalent Pipe Length . . . . . . . . . . . . . . . . . . . . . . . 22
High Altitude Pressure Switches . . . . . . . . . . . . . . . . . . . . . . . . 23
Elbow Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
These high efficiency, compact units employ induced combustion, reli-
able hot surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in upflow or
horizontal applications and may be converted for downflow applica-
tions.
LIST OF SECTIONS
COMBUSTION AIR and VENT SYSTEM . . . . . . . . . . . . . . . . . 21
START-UP AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . 29
SAFETY CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
NORMAL OPERATION AND DIAGNOSTICS . . . . . . . . . . . . . 35
REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . 37
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
START UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
LIST OF FIGURES
Upflow Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Downflow Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Horizontal Left Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Horizontal Right Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Home Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Termination Configuration - 1 Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Termination Configuration - 2 Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Termination Configuration - 2 Pipe Basement . . . . . . . . . . . . . . . . . 25
Downward Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Ambient Combustion Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Reading Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Measuring External Duct Static . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Furnace Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
LIST OF TABLES
Equivalent Length of Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Size at Furnace (All Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Estimated Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Unconfined Space Minimum Area . . . . . . . . . . . . . . . . . . . . . . . 27
Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Gas Rate (CU FT/HR) at Full Input . . . . . . . . . . . . . . . . . . . . . . 31
Inlet Gas Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Nominal Manifold Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
These furnaces are designed for residential installation in a basement,
closet, alcove, attic, recreation room or garage and are also ideal for
commercial applications. All units are factory assembled, wired and
tested to assure safe dependable and economical installation and oper-
ation.
These units are Category IV listed and may not be common vented with
another gas appliance as allowed by the National Fuel Gas Code.
5052617-UIM-E-1116

Advertisement

Table of Contents
loading

Summary of Contents for York International TM9Y Series

  • Page 1: Table Of Contents

    INSTALLATION MANUAL TWO STAGE STANDARD ECM RESIDENTIAL GAS FURNACES MODELS: TM9Y Series (96% AFUE Multi-position) LIST OF SECTIONS SAFETY ......... . . 2 COMBUSTION AIR and VENT SYSTEM .
  • Page 2: Safety

    5052617-UIM-E-1116 SECTION I: SAFETY • Proper vent installation; • Furnace operating under thermostatic control; This is a safety alert symbol. When you see this symbol on • Return air duct sealed to the furnace; labels or in manuals, be alert to the potential for personal •...
  • Page 3 5052617-UIM-E-1116 • Furnaces for upflow installation on combustible flooring shall not When outdoor air is used for combustion, the combustion air intake duct be installed directly on carpeting, tile or other combustible mate- system termination must be located external to the building and in an rial other than wood flooring.
  • Page 4: Unit Clearances To Combustibles

    5052617-UIM-E-1116 4. Where it will not interfere with proper air circulation in the confined FOR FURNACES INSTALLED IN THE COMMON- space. WEALTH OF MASSACHUSETTS ONLY 5. Where the outdoor vent terminal will not be blocked or restricted. Refer to “VENT CLEARANCES” located in SECTION VII of these For all side wall horizontally vented gas fueled equipment installed in instructions.
  • Page 5: Ductwork

    5052617-UIM-E-1116 SECTION II: DUCTWORK If a matching cased indoor coil is used, it may be placed directly on the furnace outlet and sealed to prevent leakage. If an uncased indoor coil DUCTWORK GENERAL INFORMATION with a thermoplastic drain pan is to be installed in the upflow/horizontal The duct system’s design and installation must: configuration, then extra 2”...
  • Page 6: Vertical Applications

    5052617-UIM-E-1116 COIL INSTALLATION FURNACE ASSEMBLY - MC SERIES COILS ONLY IMPORTANT MC coils are supplied ready to be installed in a horizontal position. A horizontal pan is factory installed. MC coils should be installed in all hor- izontal applications with the horizontal drain pan side down. On all installations without a coil, a removable access panel is recom- mended in the outlet duct such that smoke or reflected light would be observable inside the casing to indicate the presence of leaks in the...
  • Page 7: Pc Series Upflow Coil Installation

    5052617-UIM-E-1116 (Min) FURNACE WARM AIR PLENUM Flexible WITH 1” FLANGES Duct Connector Field Fabricated FIBERGLASS INSULATION Ductwork Do not drill Upflow Coil or Screw FIBERGLASS TAPE this flange UNDER FLANGE Secondary Drain Upflow Furnace Alternate Drain Location Primary Drain A0432-001 COMBUSTIBLE FLOOR FIGURE 6: PC Series Upflow Coil Installation BASE ACCESSORY...
  • Page 8: Horizontal Application

    5052617-UIM-E-1116 HORIZONTAL APPLICATION SUSPENDED FURNACE / CRAWL SPACE INSTALLATION The furnace can be hung from floor joists or installed on suitable blocks or pads. Blocks or pad installations shall provide adequate height to ensure that the unit will not be subject to water damage. Units may also be suspended from rafters or floor joists using rods, pipe angle supports or straps.
  • Page 9: Filters

    5052617-UIM-E-1116 RIGHT SIDE LEFT SIDE FRONT Combustion Air Inlet Combustion Air Inlet Condensate Drain Gas Pipe Gas Pipe Condensate Drain (Downflow) Entry Entry (Downflow) Vent Outlet Electrical Electrical Entry Entry Vent Outlet Condensate Drain Condensate 23” Drain Thermostat Wiring Thermostat Optional Return Air Wiring 14”...
  • Page 10: Gas Piping

    5052617-UIM-E-1116 SECTION IV: GAS PIPING SIDE RETURN GAS SAFETY Locate the “L” shaped corner locators. These indicate the size of the cut- out to be made in the furnace side panel. Refer to Figure 14. DANGER An overpressure protection device, such as a pressure regulator, Front of must be installed in the gas piping system upstream of the furnace Furnace...
  • Page 11: Nominal Manifold Pressure - High Fire

    5052617-UIM-E-1116 GAS ORIFICE CONVERSION FOR PROPANE (LP) IMPORTANT This furnace is constructed at the factory for natural gas-fired operation, but may be converted to operate on propane (LP) gas by using a An accessible manual shutoff valve must be installed upstream of the factory-supplied LP conversion kit.
  • Page 12: Electrical Power

    5052617-UIM-E-1116 SECTION V: ELECTRICAL POWER Field wiring to the unit must be grounded. Electric wires that are field installed shall conform to the temperature limitation for 63°F (35°C) rise ELECTRICAL POWER CONNECTIONS wire when installed in accordance with instructions. Refer to Table 7 in CAUTION these instructions for specific furnace electrical data.
  • Page 13: Thermostat Chart - Two Stage Ac With Two Stage Standard Ecm Furnaces

    5052617-UIM-E-1116 For additional connection diagrams for all Johnson Controls Unitary Products’ equipment refer to “Low Voltage System Wiring” document available on-line at www.upgnet.com in the Product Catalog Section. FIGURE 18: Thermostat Chart - Two Stage AC with Two Stage Standard ECM Furnaces If using a single stage air conditioning unit, connect the “Y”...
  • Page 14: Thermostat Chart - Two Stage Hp With Two Stage Standard Ecm Furnace

    5052617-UIM-E-1116 Two Stage Heat Pump - Two Stage Furnace (Hot Heat Pump or Conventional) TWO STAGE TWO STAGE FURNACE HEAT PUMP (STD ECM) THERMOSTAT TWO STAGE PSC YORKGUARD VI FURNACE CONTROL 24 – Volt Common 24 – Volt Common 24 – Volt Common Single Stage Single Stage First Stage Compressor...
  • Page 15: Twinning

    5052617-UIM-E-1116 ACCESSORY CONNECTIONS No hose clamps are needed for connecting to the condensate pan. IMPORTANT The furnace control will allow power-switching control of various accessories. ELECTRONIC AIR CLEANER CONNECTION The furnace, indoor coil, and humidifier drains may be combined and drained together.
  • Page 16 5052617-UIM-E-1116 CONDENSATE DRAIN TERMINATION NOTICE A condensate sump pump MUST be used if required by local codes, or if no indoor floor drain is available. The condensate sump pump must A loop has been added to the pressure switch vacuum hose. How- be approved for use with acidic condensate.
  • Page 17: Upflow Configuration

    5052617-UIM-E-1116 FIGURE 21: Upflow Configuration Johnson Controls Unitary Products...
  • Page 18: Downflow Configuration

    5052617-UIM-E-1116 FIGURE 22: Downflow Configuration Johnson Controls Unitary Products...
  • Page 19: Horizontal Left Configuration

    5052617-UIM-E-1116 FIGURE 23: Horizontal Left Configuration Johnson Controls Unitary Products...
  • Page 20: Horizontal Right Configuration

    5052617-UIM-E-1116 FIGURE 24: Horizontal Right Configuration Johnson Controls Unitary Products...
  • Page 21: Combustion Air And Vent System

    5052617-UIM-E-1116 SECTION VIII: COMBUSTION AIR AND 4. All PVC or ABS combustion air and vent pipe must conform to VENT SYSTEM American National Standards Institute (ANSI) and American Soci- ety for Testing and Materials (ASTM) standards D1785 (Schedule COMBUSTION AIR AND VENT SAFETY 40 PVC), D2665 (PVC-DWV), F891 (PVC-DWV Cellular Core), D2261 (ABS-DWV) or F628 (Schedule 40 ABS).
  • Page 22: Maximum Equivalent Pipe Length

    5052617-UIM-E-1116 Table 8: Maximum Equivalent Pipe Length Elevation Sea level - 2000 Elevation 6001 - 7000 Model Input (BTUH) Pipe Size (in) Max. equivalent Length (ft) Model Input (BTUH) Pipe Size (in) Max. equivalent Length (ft) 40,000 40,000 40,000 40,000 40,000 40,000 60,000...
  • Page 23: High Altitude Pressure Switches

    5052617-UIM-E-1116 Table 9: High Altitude Pressure Switches High Altitude Pressure Switches required for all installations above 5000 Feet Part Number Models S1-1PS3308 TABLE 12: Combustion Air Intake and Vent Connection Size at Furnace (All Models) FURNACE VENT CONNECTION SIZES Furnace Input Intake Pipe Size 2”...
  • Page 24: Home Layout

    5052617-UIM-E-1116 VENT CLEARANCES VENT TERMINAL FIXED AIR SUPPLY CLOSED AREA WHERE TERMINAL IS NOT PERMITTED FIXED CLOSED OPERABLE FIGURE 26: Home Layout Direct Vent Terminal Clearances Canadian Installations US Installation A. Clearance above grade, veranda, porch, deck, or 12” (30.5 cm) 12”...
  • Page 25: Termination Configuration - 1 Pipe

    5052617-UIM-E-1116 VENT SYSTEM 12” vertical separation This furnace is certified to be installed with one of two possible vent between combustion air Maintain 12” minimum 12” minimum intake and vent. configurations. clearance above below overhang highest anticipated 1. Horizontal vent system. This vent system can be installed com- 12”...
  • Page 26: Double Horizontal Combustion Air Intake And Vent Termination

    5052617-UIM-E-1116 COMBUSTION AIR SUPPLY All installations must comply with Section 5.3, Air for Combustion and VENT Ventilation of the National Fuel Gas Code, ANSI Z223.1 or Sections 7.2, 7.3 or 7.4 of CAN/CGA B149.1 or B149.2 Installation Code - latest editions.
  • Page 27: Combustion Airflow Path Through The Furnace Casing

    5052617-UIM-E-1116 Ambient Combustion Air Supply Table 13: Estimated Free Area This type installation will draw the air required for combustion from Wood or Metal Wood 20-25%* within the space surrounding the appliance and from areas or rooms Louvers or Grilles Metal 60-70% * adjacent to the space surrounding the appliance.
  • Page 28: Ambient Combustion Air

    5052617-UIM-E-1116 Vent Vent Gable Vent Gable Vent Vent Ventilated Ventilated Attic Optional Attic Top Above Inlet (a) Top Above Insulation Insulation Soffit Outlet Soffit Outlet Vent Air (a) Outlet Vent Air (b) Air (a) Water Heater Water Water Inlet Inlet Inlet Inlet Heater...
  • Page 29: Start-Up And Adjustments

    5052617-UIM-E-1116 WARNING CARBON MONOXIDE POISONING HAZARD Failure to follow the steps outlined below for each appliance connected to the venting system being placed into operation could result in carbon- monxide poisoning or death. The following steps shall be followed for each appliance connected to the venting system being placed into operation, while all other appliances connected to the venting system are not in operation: 1.
  • Page 30 5052617-UIM-E-1116 CALCULATING THE FURNACE INPUT (NAT. GAS) It is recommended that when the gas supply is first connected to the furnace, the ground union be loosened until the odor of gas is detected. Burner orifices are sized to provide proper input rate using natural gas When gas is detected, immediately tighten the union and check for gas with a heating value of 1030 BTU/Ft (38.4 MJ/m...
  • Page 31: Gas Rate (Cu Ft/Hr) At Full Input

    5052617-UIM-E-1116 Table 16: Gas Rate (CU FT/HR) at Full Input Seconds For Size of Test Dial Seconds For Size of Test Dial 1 Revolution 1 Revolution 1 Cu Ft 2 Cu Ft 5 Cu Ft 1 Cu Ft 2 Cu Ft 5 Cu Ft 1800 1636...
  • Page 32: Gas Valve

    5052617-UIM-E-1116 IMPORTANT HIGH STAGE REGULATOR ADJUSTMENT OUTLET PRESSURE The inlet gas pressure operating range table specifies what the mini- PORT VENT mum and maximum gas line pressures must be for the furnace to PORT operate safely. The gas line pressure MUST BE a minimum of: •...
  • Page 33: Measuring External Duct Static

    5052617-UIM-E-1116 After about 5 minutes of operation, determine the furnace temperature 2. Operate the furnace a minimum of (10 minutes) to ensure stable rise. Take readings of both the return air and the heated air in the ducts, operation of the combustion process. about six feet (1.83 m) from the furnace where they will not be affected 3.
  • Page 34: Safety Controls

    5052617-UIM-E-1116 Table 19: Blower Performance CFM - Any Position (without filter) Bottom Airflow Data (SCFM) Models Speed Ext. Static Pressure (in. H High 1290 1260 1220 1160 1100 1040 Medium High 1170 1140 1110 1070 1040 Medium Medium Low High 1402 1374 1354...
  • Page 35: Normal Operation And Diagnostics

    5052617-UIM-E-1116 LIMIT CONTROLS During burner operation, a momentary loss of power for 50 milliseconds or longer will de-energize the gas valve. When the power is restored, There is a high temperature limit control located on the furnace vesti- the gas valve will remain de-energized and the ignition sequence will bule panel near the gas valve.
  • Page 36 5052617-UIM-E-1116 4 RED FLASHES: This indicates that the main limit switch has opened 13 RED FLASHES: This fault code indicates that the 2nd stage (high) its normally closed contacts. The control will operate the supply air pressure switch is open with a call for 2nd stage heating (high fire) pres- blower and inducer while the open limit condition exists.
  • Page 37: Replacement Parts List

    5052617-UIM-E-1116 SECTION XII: REPLACEMENT PARTS LIST DESCRIPTION DESCRIPTION FABRICATED PARTS Continued MOTOR PANEL, TOP BLOWER, COMBUSTION RAIL, BLOWER (2 req’d) MOTOR, DIRECT DRIVE BLOWER SHELF, BLOWER ELECTRICAL MISCELLANEOUS CONTROL, FURNACE BAG, PARTS CONTROL, TEMPERATURE BRACKET, DOOR IGNITER DIAGRAM, WIRING SENSOR, FLAME FERRULE (3 req’d) SWITCH, DOOR GASKET, FOAM (Door) (1.5 ft req’d)
  • Page 38: Wiring Diagram

    5052617-UIM-E-1116 SECTION XIII: WIRING DIAGRAM FIGURE 41: Wiring Diagram Johnson Controls Unitary Products...
  • Page 39: Start Up Sheet

    5052617-UIM-E-1116 SECTION XIV: START UP SHEET 33" 96% AFUE Two Stage Standard ECM Gas Furnace Start Up Sheet Proper furnace start up is critical to customer comfort and equipment longevity Owner Information Equipment Data Furnace Configuration Filter, Thermostat, Accessories Connections -- All Per Installation Instructions and Local Code Condensate Management Venting Exhaust...
  • Page 40 Air Side: Continuous Fan (STD ECM) Cycle Test Clean Up Owner Education Subject to change without notice. Published in U.S.A 5052617-UIM-E-1116 Copyright © 2016 by Johnson Controls, Inc. All rights reserved. Supersedes: 5052617-UIM-D-1016 York International Corp. 5005 York Drive Norman, OK 73069...

Table of Contents