Sony DCM-M1 Service Manual page 188

Minidisc av recorder
Hide thumbs Also See for DCM-M1:
Table of Contents

Advertisement

Adjusting method
Steps
Page
Address
1
06
40
2
06
41
3
0F
43
4
5
6
7
8
9
10
0F
43
11
12
13
14
15
0F
43
Processing after completion of adjustment
Steps
Page
Address
1
06
40
2
06
41
Data
Press the y key.
02
01
Press the y key.
Press the y key.
00
Place the Siemens star at 2.0 m forward position from the lens front surface.
Shoot the Siemens star with the zoom at TELE end.
Adjusting the lens direction, make the center of Siemens star and the center of optical axis
deviation specification frame (monitor screen) concurrent.
Shoot the Siemens star with the zoom at WIDE end.
On the monitor TV, check which area of the optical axis deviation specification frame the
center of Siemens star enters.
At this time, measure the center deviation "L1" (distance between center of Siemens star
and center of optical axis deviation specification frame).
Read correction data (D
Area
1
2
3
4
5
6
7
8
Set the read correction data, and press the y key.
D43
Shoot the Siemens star with the zoom at TELE end.
Adjusting the lens direction, make the center of Siemens star and the center of optical axis
deviation specification frame concurrent.
Shoot the Siemens star with the zoom at WIDE end.
Measure the center deviation "L2" (distance between center of Siemens star and center of
optical axis deviation specification frame).
Compare L1 and L2 to make sure that L2 is smaller than L1.
If larger, set data: 00 and press the y key.
Data
Press the y key.
00
Press the y key.
00
Work Description
) according to the area in the following table.
43
Deviation phase
22.6° – 67.5°
67.6° – 112.5°
112.6° – 157.5°
157.6° – 202.5°
202.6° – 247.5°
247.6° – 292.5°
292.6° – 337.5°
337.6° – 22.5°
Work Description
– 14 –
Correction data
01
02
03
04
05
06
07
08

Advertisement

Table of Contents
loading

Table of Contents