Flange back adjustment (2)
Subject more than 500 m away
Subject
(which should be clear contrast such as a building)
Measurement point
Check operation on monitor TV
Measuring instrument
(Camera-through screen)
Adjustment page
0F
Adjustment address
24 – 29, 36 – 3D
Note: For the data display, the data at the time when address was set is displayed, and it is not updated.
Check data variation while repeating address change and resetting (change address from "02" to "01", and then return it to "02").
Adjusting method
Page
Address
Steps
1
2
06
02
3
06
01
4
5
06
01
6
06
02
Processing after completion of adjustment
Steps
Page
Address
1
06
01
2
Data
With the zoom lens at TELE end, shoot the subject distant over 500 m (such as a building
having clear contrast).
(At this time, the subjects distant below 500 m must not be displayed on the screen.)
Check that the data is "00".
Press the y key.
13
Cover the lens with ND filter, and adjust so as to get the optimum image.
Press the y key.
29
(The flange back adjustment is carried out, and the data are automatically entered to
page: F, address: 24 – 29 and 36 – 3D.)
Check that the data becomes "01". (Note)
Data
Press the y key.
00
Perform "Flange Back Check".
Work Description
Work Description