9. Device errors

9.1. Smoke pipe system error

In case that the ventilator for air circulation is damaged, the
input of pellet into the furnace will be stopped and an error
will be displayed, blocking the fireplace activity.

9.2. Error of motor for pellet input

In case that the motor is not in function, the fireplace
continues to work until all pellets in the storage are spent.
After that, the fireplace stops its activity.

9.3. Activation error

In case there is no flame during the activation process an
activation error will be displayed.
9.4. Break in supply of electrical energy
In case that there is no supply of electrical energy, all devices
stop working and in the next three to five minutes a minimal
dosage of fume could get out of the fireplace. This
consequence has no impact on safety. When the fireplace
gets supplied with electrical energy again, an error will be
36