Kovan Eko line User Manual

Kovan Eko line User Manual

Automatic fireplace on pellets

Advertisement

Quick Links

www.kovan.ba
USER MANUAL
INSTALLATION, USE
AND MAINTENANCE
Automatic fireplace on pellets
<<EKO-LINE>>

Advertisement

Table of Contents
loading

Summary of Contents for Kovan Eko line

  • Page 1 USER MANUAL INSTALLATION, USE AND MAINTENANCE Automatic fireplace on pellets <<EKO-LINE>>...
  • Page 2 USER MANUAL www.kovan.ba •1. EC statement of compliancy •2. Warranty •3. General warnings •3.1. Basic safety rules •4. Instructions for safe work •4.1. Explanation of signs •4.2. In case of fuel gass smell appearance •4.3. Transfer to another type of fuel •4.4 Maintenance...
  • Page 3 USER MANUAL www.kovan.ba •7.2. Ignition of the fireplace •7.3. Regulation •7.4. Other functions •7.4.1. Hysteresis •7.4.2. Cleaning period •7.4.3. Cleaning duration •7.4.4. Language •7.4.5. Input - phone •7.4.6. Clock •7.4.7. Timer •8. Cleaning and maintenance •8.1. Cleaning of metal components •8.2 Cleaning of outer mantle...
  • Page 4 The European directive 73/23 EEZ and later amendments 93/68, 89/336 EEC and later amendments 92/31 EEC, 93/97 „KOVAN“M.I. - ul. Branilaca grada bb, 75320 Gračanica, under our sole liability, we state that the series of Ekoline fireplaces has been designed and constructed as required by safety standards for the CE mark.
  • Page 5 We recommend you to confide putting the fireplace into operation to a professionally trained individual or contact our Technical Service «Kovan» who will on your request put the boiler into operation in manner that is specified by this manual.
  • Page 6 « Kovan » that sold you the fireplace or to your distributor. All local regulations, including national and European standards must be followed while installing the device.
  • Page 7 Technical services «Kovan» m.i.  The fireplace is an electric device and in accordance...
  • Page 8 USER MANUAL www.kovan.ba 4. Instructions for safe work 4.1. Explanation of signs Instructions for safe work are marked with a warning triangle Words (Caution, Warning, and Danger) mark the importance of danger which could appear if measures for the damage mitigating would not be respected.
  • Page 9 USER MANUAL www.kovan.ba 4.2. In case of fuel gas smell appearance  Turn off the fireplace  Open windows and doors  Seek instructions or help from a qualified person or your serviceman In case that the chimney has caught fire (which can be...
  • Page 10 USER MANUAL www.kovan.ba 4.3. Transfer to another type of fuel Installment of additional devices and using other type of fuel is not allowed as well as any kind of changes or alternations on the fireplace itself. 4.4. Maintenance The user is responsible for the safety and the environmental acceptability of the installation.
  • Page 11 USER MANUAL www.kovan.ba 5. Information about the fireplace 5.1. Quality statement The construction of the fireplace is in accordance with the European Directive CEE 73/23 and amendments 93/68 CEE, CEE 89/336 and amendments 93/68 CEE; 92/31CEE; 93/97 CEE and European norms. Our product complies with the standards of burning tests, electric tests in accordance with the standards EN 60335 and EN 60366.
  • Page 12 USER MANUAL www.kovan.ba 5.2. Fireplace type EKO-1-7.5 7,5 kW Explanation of simbols: EKO – ecological fireplace (fulfills all requirements of European Directives) 1 – number of production version 7.5 – heating power 5.3. Technical information Parameters 7,5 kW Fireplace type EKO-1-7.5...
  • Page 13 USER MANUAL www.kovan.ba 5.4. Fireplace description The fireplace is constructed so as to operate with pellet. The construction of the fireplace is made of steel, carried out by plate welding. It consists of an inner ardent and outer protective mantle, a circuit of the torch and pellet storage.
  • Page 14 USER MANUAL www.kovan.ba The conductor wire is ensured with a protective cable, sections 3x1.5mm All components of the fireplace that are exposed to high temperatures are protected with fire proofed colors that resist temperatures up to 700 degrees of Celsius. All other parts are protected with an anticorrosive color in two mantles.
  • Page 15: Fireplace Installation

    USER MANUAL www.kovan.ba 5.6. Scope of delivery  Fireplace  Instructions for handling and use  Warranty card 5. Fireplace installation Note: Installation, connection to voltage and activation should be done after reading the user manual 6.1. Important instructions Before the first commissioning, carefully study the technical manual.
  • Page 16 USER MANUAL www.kovan.ba 6.2. Selection of the mounting location It is recommended to install the fireplace into a big centred room in the house in order to ensure equal distribution of warm air. It is important to ensure enough air in the fireplaces room.
  • Page 17 USER MANUAL www.kovan.ba burner. Before letting the fireplace in operation, check the patency of the chimney, flue pipe, as well as any devices for protection from the wind. 6.4. Preparing for installation The fireplace is supplied wrapped in protective foil. Beneath the sheet, on top of the fireplace, you can find the corresponding instructions and the guarantee card.
  • Page 18 USER MANUAL www.kovan.ba All regulatory, controlling and safety appliances of boiler have been wired and tested in the factory. On an accessible place of the boiler ensure a connecting place with a 1-phase outlet. The place of the outlet should be properly selected so that the socket device is always easily accessible.
  • Page 19 USER MANUAL www.kovan.ba Note:  Electrical connection must match the current regulations for electrical installations in households  You must have a protective conductor  In the case of a direct power cable connect, it is necessary to install a switching device that provides a reliable turning off of the fireplace.
  • Page 20 USER MANUAL www.kovan.ba Electric switch on/switch off the boiler Switching on: Switch on the fireplace by plugging the electrical cable into an accessible 1-phase outlet on the wall. The illuminated display shows that the fireplace is under voltage. Wait for a few seconds that the system needs to set up.
  • Page 21 7. Configuration of the fireplace 7.1. Function description The Eko line fireplace has electronics which supports three operating modes, P1, P2, P3. These three operating modes enable easy set up of the fire to the needs of users.
  • Page 22 USER MANUAL www.kovan.ba 7.2. Ignition of the fireplace Hold the button until on the display appears „ignition“ . The fireplace has an automatic ignition process. The burner needs to be cleaned before every start of the fireplace. In cases of first ignition or ignition after the disappearance of pellets is necessary to put a handful of pellets into the burner.
  • Page 23 USER MANUAL www.kovan.ba Parameters that are needed to be changed for P1 mode are: To change the value press the button and change it with buttons...
  • Page 24 USER MANUAL www.kovan.ba Parameters that are needed to be changed for P2 mode are: To change the value press the button and change it with buttons...
  • Page 25 USER MANUAL www.kovan.ba Parameters that are needed to be changed for P3 mode are: To change the value press the button and change it with buttons...
  • Page 26 USER MANUAL www.kovan.ba 7.3. Regulation Enter the menu by pressing the button. If you want to change the value, press the button. By pressing the Up or Down button you can change the value. After setting the wanted value, press the button to confirm.
  • Page 27 USER MANUAL www.kovan.ba 7.4. Other functions 7.4.1. Hysteresis Difference between the current and wanted temperature before re-firing. 7.4.2. Cleaning period The period of cleaning the burner of the fireplace depends on the quality of pellets. This period is on average 15 minutes.
  • Page 28 USER MANUAL www.kovan.ba 7.4.3. Cleaning duration Duration of burner cleaning. The duration is on average 15 seconds. 7.4.4. Language Languages that can be used:  English  Bosnian  German  Slovenian...
  • Page 29 USER MANUAL www.kovan.ba 7.4.5. Input - phone Enables to switch on the fireplace via telephone. If you don't have installed this device you must set its value to „disabled“. 7.4.6. Clock Is used to set up the current day and time.
  • Page 30 USER MANUAL www.kovan.ba 7.4.7. Timer This item allows you to configure a lightning and extinguishing of the fire on a set time. If you do not want to use this function, then set it to "Off". If you want to use the timer, then you have the choice of the following options: ...
  • Page 31: Cleaning And Maintenance

    USER MANUAL www.kovan.ba  Sets the time to stop the fireplace  Second start of the fireplace (2. START):  Sets the time to start the fireplace for a second time (if you don't want to use this feature, then set it to 24:00) ...
  • Page 32 USER MANUAL www.kovan.ba Warning : Before you clean the fireplace disconnect it from voltage. Unplug the supply cable or turn of the breaker if the fireplace is equipped with an inseparable cable, i.e. if it is directly connected. The slug is removed from the furnace by digging or with a special vacuum cleaner for slug.
  • Page 33 USER MANUAL www.kovan.ba Alert: The use of aggressive chemicals or detergent can damage the surface of the chimney. 8.2. Cleaning of outer mantle To clean the outer mantle of the fireplace use a soft, wet cloth and nonaggressive detergents. Do not clean the surface with cold water, especially not if the surface is extremely hot.
  • Page 34 USER MANUAL www.kovan.ba 8.4. Cleaning of the glass The glass has a self-cleaning function, which means when the fireplace is activated, air flows over its surface in order to prevent the storage of ash and slug on it. Despite this fact, after a few hours of heating the glass becomes darker.
  • Page 35 USER MANUAL www.kovan.ba  Careful cleaning of the furnace  Examination and cleaning of smoke pipes  Examination and possible exchange of silicon joints on the fireplace door  Examination and cleaning of mechanical components (motor and ventilator)  Exchange of igniters 8.7.
  • Page 36 USER MANUAL www.kovan.ba 9. Device errors 9.1. Smoke pipe system error In case that the ventilator for air circulation is damaged, the input of pellet into the furnace will be stopped and an error will be displayed, blocking the fireplace activity.
  • Page 37 USER MANUAL www.kovan.ba displayed. When the fireplace has cooled down (after ten minutes), clean the furnace and reactivate it. Note: In cases of increased voltage supply the fireplace is ensured with a breaker. The electrical connection has to be grounded. The producer hedges...
  • Page 38 USER MANUAL www.kovan.ba DISORDER CAUSE HANDLING Alarm: 1.There is no 1.Fill up the pellets Ignition error pellets tank The fireplace has 2.Burner is 2.Clean the burner received the signal blocked by ash for ignition, but and scoria cannot light the 3.Clean the flue...
  • Page 39 USER MANUAL www.kovan.ba DISORDER CAUSE HANDLING Alarm: 1. There is no 1. Fill up the Fireplace turned pellets pellets tank 2. Burner is 2. Clean the blocked by ash burner and scoria 3. Smoked flue 3. Clean the flue tubes tubes 4.
  • Page 40 USER MANUAL www.kovan.ba DISORDER CAUSE HANDLING Alarm: 1. Damaged 1. Request System error controller assistance from authorized service DISORDER CAUSE HANDLING The fireplace 1. Dirty burner and 1. Clean the cannot reach the flue tubes burner and the set temperature flue tubes 2.
  • Page 41 USER MANUAL www.kovan.ba DISORDER CAUSE HANDLING Frequent 1. Bad pellets 1. Increase „air of griminess of the quality (causes the burning“ 1% - 3% fireplace deficit of air of in relation to the burning) already set up adjustment A certain quantity 1.
  • Page 42 USER MANUAL www.kovan.ba DISORDER CAUSE HANDLING Enormously 1. Very bad pellets 1. Contact the increased with weak caloric supplier of consumption of power manufacturer of pellets (no change pellets of outside 2. Large amount of temperature) dust in the pellets 11.
  • Page 43 USER MANUAL www.kovan.ba The colour of pellets should be approximately equal to the colour of the wood from which it is made. One pack of pellets may not contain more than 1% dust or sawdust in the total content of the package.

Table of Contents