MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
Module
70
OPEL_CE
EXTRA
71
EXT_CONT
EXTRA
72
P_CON
Power supply I/O
73
ANT_CONT
TUNER
74
ILLMI_DET
EXTRA
75
BU_DET
Power supply
76
ACC_DET
Power supply
77
(PWIC_SVR)
PWIC
78
PWIC_MUTE
PWIC
79
PWIC_STBY
PWIC
80
LX_CON
LX_M
81
RESET2
82
MUTE
AUDIO
83
MUTE_ACOUT
AUDIO
84
MUTE_SUBOUT
AUDIO
85
MUTE_PRE_R
AUDIO
86
MUTE_PRE_L
AUDIO
87
LINE_MUTE
EXTRA
88
NC
89
PWIC_DC_DET
PWIC
90
LX_RST
LX_M
91
LX_MUTE
LX_M
92
LX_REQ_M
LX_M
93
RDS_NOISE
TUNER
94
AVSS
95
TUN_SMETER
TUNER
96
VREF
97
AVCC
98
LX_DATA_S
LX_M
99
LX_DATA_M
LX_M
100
LX_CLK
LX_M
I/O
Application
I/O
External display control request
O
External amp control
External amp control terminal
O
Power antenna control
I
Dimmer ILL detect
I
Momentary power down detect
I
ACC Power supply detect
O
SVR electrical discharge circuit
O
Power IC MUTE terminal
O
Power IC standby control
O
Startup request to slave unit
O
MUTE terminal for reset
O
MUTE terminal
I/O
IC2 ACOUT MUTE
I/O
IC2 SUBOUT MUTE
I/O
PRE_OUT MUTE Rch
I/O
PRE_OUT MUTE Lch
I
Line MUTE detect
O
Not used
I
DC offset detect terminal
O
Hard reset to slave unit
I
Mute request from slave unit
O
Communication request to slave unit
I
FM noise detect terminal
-
I
S-meter input
I
Analog reference potential
-
I
Data from slave unit
O
Data to slave unit
I/O
LX BUS clock
KDC-MP6025/MP625/MP858
KDC-W6527/W6527Y
Truth Value
Processing Operation Description
Table
External display
Power ON : H, Power OFF : Hi-Z, All OFF : Hi-Z
Tuner ON : H
L : ON, H : OFF
BU detect : L, BU no detect and Momentary
power down : H
ACC detect : L, ACC no detect : H
Power OFF and Momentary power down, for
5s : H and then L
All OFF and Momentary power down : L, TEL mute : L
Power ON : H, Power OFF : L
H : Slave unit ON, L : Slave unit OFF
Output : L
ON : H, OFF : L
Muting of CD, MD and LXBUS
Muting of CD, MD and LXBUS in 2 zones
M MUTE R is L : L (CD), Momentary power down : L,
Only in 2 zones and NAVI interruption, Hi-Z fixed.
M MUTE R is L : L (CD), Momentary power down : L,
Only in 2 zones and NAVI interruption, Hi-Z fixed.
TEL mute : 1V or less, NAVI mute : 2.5V or more,
1V or less and 2.5V or more : NAVI mute (J-type)
Output : L
H : Reset, L : Normal
H : Mute ON, L : Mute OFF
PON is input