OPERATING PROCEDURE
12. Removing the compressor
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove the electric parts box. (See Photo 3)
(4) Remove the bell mouth. (See Photo 7)
(5) Remove the 3 valve bed fixing screws (4
4 ball valve fixing screws(5
(6) Remove the 3 rear panel fixing screws (5
(7) Remove the cover panel fixing screw (5
the front side of cover panel.
(8) Remove the 3 points of the compressor fixing nut with a
monkey wrench.
(9) Remove the braze part of compressor discharging / inlet.
13. Removing the accumulator.
(1) Remove the compressor. Or remove the rear panel.
(2) Remove the pipe of accumulator intake and outlet.
10) and the
16) to remove the valve bed.
15) to the panel.
15) to remove