Mitsubishi Electric PU(H)-P-GAA Installation Manual
Mitsubishi Electric PU(H)-P-GAA Installation Manual

Mitsubishi Electric PU(H)-P-GAA Installation Manual

Mr. slim
Hide thumbs Also See for PU(H)-P-GAA:

Advertisement

Quick Links

Air-Conditioners
PU(H)-P·GAA

INSTALLATION MANUAL

For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende Bedienungsanleitung
und die Installationsanleitung der Innenanlage gründlich durchlesen die Klimaanlage.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil
intérieur pour une utilisation sûre et correcte.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het binnenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso correcto y seguro, lea detalladamente este manual y el manual de instalación de la unidad interior
antes de instalar la unidad de aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente il presente manuale ed il manuale d'installazione dell'unità
interna prima di installare il condizionatore d'aria.
E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™
°È· ÛˆÛÙ‹ Î·È ·ÛÊ·Ï‹ ¯Ú‹ÛË, ‰È·‚¿ÛÙ ÚÔÛÂÎÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ Î·ıÒ˜ Î·È ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ÂÁηٿÛÙ·Û˘
Ù˘ ÂÛˆÙÂÚÈ΋˜ ÌÔÓ¿‰·˜, ÚÔÙÔ‡ ÂÁηٷÛÙ‹ÛÂÙ ÙË ÌÔÓ¿‰· ÙÔ˘ ÎÏÈÌ·ÙÈÛÙÈÎÔ‡.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade interior
antes de instalar o aparelho de ar condicionado.
INSTALLATIONSMANUAL
Læs af sikkerhedshensyn denne manual samt manualen til installation af indendørsenheden grundigt, før du
installerer klimaanlægget.
INSTALLATIONSMANUAL
Läs bruksanvisningen och inomhusenhetens installationshandbok noga innan luftkonditioneringen installeras
så att den används på ett säkert och korrekt sätt.
MONTAJ ELK‹TABI
Emniyetli ve do¤ru kullanım için, klima cihazını monte etmeden önce bu kılavuzu ve iç ünite montaj kılavuzunu
tamamıyla okuyun.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для обеспечения безопасной и надлежащей эксплуатации внимательно прочтите данное
руководство и руководство по установке внутреннего прибора перед установкой кондиционера.
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
°π∞ ∞À∆√¡ ¶√À ∫∞¡∂π ∆∏¡ ∂°∫∞∆∞™∆∞™∏
PARA O INSTALADOR
TIL INSTALLATØREN
FÖR INSTALLATÖREN
MONTÖR ‹Ç‹N
ДЛЯ УСТАНОВИТЕЛЯ
English
Deutsch
Français
Nederlands
Español
Italiano
∂ÏÏËÓÈο
Português
Dansk
Svenska
Türkçe
Русский

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PU(H)-P-GAA

  • Page 1: Installation Manual

    Air-Conditioners PU(H)-P·GAA INSTALLATION MANUAL FOR INSTALLER English For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende Bedienungsanleitung und die Installationsanleitung der Innenanlage gründlich durchlesen die Klimaanlage.
  • Page 2: Table Of Contents

    • Use only accessories authorized by Mitsubishi Electric and ask a dealer or • If the air conditioner is installed in a small room, measures must be taken to an authorized technician to install them.
  • Page 3: Installation Location

    1. Safety precautions 1.2. Before installation (relocation) Caution: • Be extremely careful when transporting the units. Two or more persons are • Install the drainpipe according to this Installation Manual to ensure proper needed to handle the unit, as it weighs 20 kg or more. Do not grasp the drainage.
  • Page 4: Installing The Outdoor Unit

    2. Installation location 2.4.2. When installing a single outdoor unit (Refer to the last page) Minimum dimensions are as follows, except for Max., meaning Maximum dimensions, indicated. The figure in parentheses are for P100-140 models. Refer to the figures for each case. 1 Obstacles at rear only (Fig.
  • Page 5: Installing The Refrigerant Piping

    4. Installing the refrigerant piping 4.1. Precautions for devices that use R407C refrigerant • Do not use the existing refrigerant piping. • Do not use crushed, misshapen, or discolored tubing. The inside of the tub- ing should be clean and free from harmful sulfuric compounds, oxidants, dirt, debris, oils and moisture.
  • Page 6 4. Installing the refrigerant piping 4.4. Refrigerant pipe airtight testing method (1) Connect the testing tools. • Make sure the stop valves are closed and do not open them. • Add pressure to the refrigerant lines through the service port of the liquid stop valve.
  • Page 7: Drainage Piping Work

    5. Drainage piping work Outdoor unit drainage pipe connection When drain piping is necessary, use the drain pan (optional parts). 6. Electrical work For PU(H)-P·YGAA 6.1. Precautions (Fig. 6-1) • The compressor will not operate unless the power supply phase connection is cor- rect.
  • Page 8: Test Run

    6. Electrical work 6.3. Field electrical wiring P25V P35V P50V P60V P71V P100V P35Y P50Y P60Y P71Y P100Y P125Y P140Y Outdoor unit model Outdoor unit Power supply ~/N (single), 50 Hz, 230 V 3N~(3phase), 50 Hz, 400 V Outdoor unit input capacity 16 A 25 A 32 A...
  • Page 9: System Control (Fig. 8-1)

    8. System control (Fig. 8-1) A Outdoor unit E SW 1 - 3 ~ 6 * Set the refrigerant address using the DIP switch of the outdoor unit. B Indoor unit 1 Wiring from the Remote Control C Master remote controller This wire is connected to TB5 (terminal board for remote controller) of the indoor unit 3 4 5 6 D Subordinate remote controller...
  • Page 10 This product is designed and intended for use in the residential, commercial and light-industrial environment. • Low Voltage Directive 73/23/ EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following 336/ EEC EU regulations: Please be sure to put the contact address/telephone number on this manual before handing it to the customer.