Automatic Defrost Function; Leakage Detection; Positioning Of The Storage Rack And Shelf - Dometic HiPro 3000 Instruction For Use & Installation Instructions

Dometic minibar instruction for use & installation instructions
Hide thumbs Also See for HiPro 3000:
Table of Contents

Advertisement

Operation
4.4

Automatic defrost function

The first defrosting phase commences 39
hours after the initial operation and lasts for
two hours.
After this, the device operates for 22 hours at
a time, followed by adefrosting period of 2
hours.
CAUTION!
The ice layer must never be
removed using force, nor
must the defrosting process ever be accele-
rated using a heater.!
4.5

Leakage detection

The electronics carry out a leakage test after
every defrosting period (every 24 hrs) by measu-
ring the temperature at the evaporator by means
of a second sensor.If the electronics detect a
leak, the miniBar is automatically switched off .
The LED for the interior lighting changes after
approx. 10 secs. to a continuous flashing. (The
LED of the door-opening control flashes synchro-
nously , if available.)
Please contact the authorized Dometic
Service if a failure occurs.
HiPro miniBars, which are designed for use on
sea vessels, are equipped with a bimetal sen-
sor switch instead ! Malfunction of the cooling
unit is not shown via the LEDs.
4.6
Positioning of the storage
rack and shelf
Pull out the storage rack until it is blocked.
Press in the lock of both running rails.
Remove storage rack and running rails and
place it at the desired position.
Remove storage rack and running rails and
place it at the desired position. After clicking
in the the storage rack it is secured against
pulling out completely again.
Fig. 31
1
3
5
(5 / 6) To fit the storage shelf, the reverse order
applies.
16
2
Fig. 32
4
Fig. 34
6
Fig. 36
Fig. 33
Fig. 35
Fig. 37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipro 4000Hipro 6000Hipro vision

Table of Contents