Siemens Simatic VS 710 Quick Reference Manual
Siemens Simatic VS 710 Quick Reference Manual

Siemens Simatic VS 710 Quick Reference Manual

A highly compact stand-alone image processing system

Advertisement

SIMATIC
VS 710
Quick Reference Guide
A5E00032597-02
Edition 11/2001

Advertisement

Table of Contents
loading

Summary of Contents for Siemens Simatic VS 710

  • Page 1 SIMATIC VS 710 Quick Reference Guide A5E00032597-02 Edition 11/2001...
  • Page 2 Sugges- tions for improvement are welcome. Technical data subject to change. Copyright W Siemens AG 1999-2001 All Rights Reserved The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages.
  • Page 3: Table Of Contents

    ......Function in Productive Mode ......SIMATIC VS 710 A5E00032597-02...
  • Page 4 ......Observing the Setup Guidelines ......SIMATIC VS 710 A5E00032597-02...
  • Page 5: Product Overview

    SIMATIC VS 710 is a highly compact stand-alone image processing system in which the camera, computer, and peripherals are integrated in a single unit. SIMATIC VS 710 has the following advantages to offer users who require an all-in-one image processing system for inspection, monitoring of production, and parts identification: •...
  • Page 6: Applications

    SIMATIC VS710 Quick Reference Guide Applications SIMATIC VS 710 is suitable for use in all areas, including the electrical, engineering, electronics, automobile, pharmaceuticals, cosmetics, food, and packaging industries. The system has a wide range of applications in product monitoring, quality control, and parts identification.
  • Page 7: Accessories

    6ES7972-0BA40-0XA0 (without PG socket) 6ES7972-0BB40-0XA0 (with PG socket) Note The accessories listed in the above table are not supplied with the device and must be ordered separately. Standard accessories are listed in catalog ST70 and ST50. SIMATIC VS 710 A5E00032597-02...
  • Page 8: Vs 710 Hardware

    100 MHz 80486 CPU (AMD) with direct image buffer access • 16 Mbyte main memory DRAM module (SO-DIMM) • 16 Mbyte IDE flashdisk (see Section 2.9) • 256 Kbyte flash EPROM as BIOS memory • 2 Mbyte image buffer SIMATIC VS 710 A5E00032597-02...
  • Page 9: Mounting The Vs 710

    To the support socket on the casing • Using the mounting bracket supplied (not included in the VS 710 OEM package) Mounting bracket 1/4” support socket M4 screw threads Figure 1 Mounting Fixtures on the VS 710 SIMATIC VS 710 A5E00032597-02...
  • Page 10: Dimensions, Mounting Fixtures

    The dimensions are dependent on the type of mounting (with or without a mounting bracket attached). 13.5 80.6 16.5 screw threads on 3 sides depth: 8mm depth: 8mm American coarse thread 1/4” 20 UNC depth: 6mm depth: 8mm depth: 8mm Figure 2 Dimensions with No Mounting Bracket Attached SIMATIC VS 710 A5E00032597-02...
  • Page 11 Quick Reference Guide SIMATIC VS710 86.6 Figure 3 Dimensions with a Mounting Bracket Attached (Side Mounting) Figure 4 Dimensions with a Mounting Bracket Attached (Top Mounting) SIMATIC VS 710 A5E00032597-02...
  • Page 12: Mounting Bracket

    VS 710 with Mounting Bracket Attached Lens Socket The lens socket fits all commercial C-mount standard lenses. Note: the set screw on the lens socket is meant for factory settings only. A readjustment of the lens position is not allowed. SIMATIC VS 710 A5E00032597-02...
  • Page 13: Hardware Interfaces

    Quick Reference Guide SIMATIC VS710 Hardware Interfaces The SIMATIC VS 710 has ports on the back panel for connecting up peripherals (DP PROFIBUS, VGA, RS232, digital I/O) and the 24 volt power supply. A terminal screw is in place for grounding.
  • Page 14: Power Supply - Connector Pinout

    (Voltage range: 20.4 to 28.8 volts) The power supply connector has the following pinout: Signal 24 volts 24 volts Ground Ground Maximum current per pin = 1 A. The connector acts as a means of isolation from the 24-volt power supply. SIMATIC VS 710 A5E00032597-02...
  • Page 15: 24 Vdc Power Supply

    VDE 0100 Part 410 / HD 384-4-41 / IEC 364-4-41 (as functional extra-low voltage with protective separation), or VDE 0805 / EN 60950 / IEC 950 (as safety extra-low voltage (SELV)), or VDE 0106 Part 101. SIMATIC VS 710 A5E00032597-02...
  • Page 16: Digital Input / Output - Connector Pinout

    Output current: 0.5 A. Rated load voltage DC 24 V • Maximum current per pin = 1 A. Warning DI and D0 are galvanically coupled by ground pins 2 and 11. 2x 24 VDC 4x 24 VDC/0.5 A, P.D./RES, 5 W tungsten SIMATIC VS 710 A5E00032597-02...
  • Page 17: Wiring Diagram (Digital Input Points)

    DO 3 DI 0 DI 0 DI 0 DI 1 DI 1 Figure 9 Connection Diagram Showing Digital Input Points DI 0, DI 1 Internal Data Bus internal Figure 10 Basic Circuit Diagram Showing Digital Input Points SIMATIC VS 710 A5E00032597-02...
  • Page 18: Wiring Diagram (Digital Output Points)

    DO 1 DO 2 DO 2 DO 3 DO 3 DI 0 DI 1 Figure 11 Connection Diagram Showing Digital Output Points Internal Data Bus DO... internal Figure 12 Basic Circuit Diagram Showing Digital Output Points SIMATIC VS 710 A5E00032597-02...
  • Page 19: Dp Connector Pinout

    The DP interface operates on the slave principle and is designed as a floating interface. It has a maximum data transfer rate of 12 Mbps. When using a point-to-point connection with a transmission rate of 12 Mbps, a line length of 100 m may be used. SIMATIC VS 710 A5E00032597-02...
  • Page 20: Vga Connector Pinout

    Not assigned Not assigned Horizontal sync Vertical sync Not assigned Shield On connector casing Note Connect your VGA monitor with the standard VGA cable. The distance between monitor and VS 710 should not exceed 2.5 m. SIMATIC VS 710 A5E00032597-02...
  • Page 21: Rs232 Connector Pinout

    The serial port is a fully-fledged RS232 interface. The ground pin is referenced to the internal ground. The interface is configured as a COM1 port and can be addressed as such. The maximum line length is 10 m with a transmission rate of 115 Kbps. SIMATIC VS 710 A5E00032597-02...
  • Page 22: Ide Flashdisk

    This “flashdisk” solid-state memory can be used to boot MS-DOS and store application programs. Note The deleting and programming cycles per logical sector of the IDE flashdisk are limited to 300,000 cycles due to physical properties. SIMATIC VS 710 A5E00032597-02...
  • Page 23: Connecting The Vs 710

    The CCD sensor orifice must always be closed, either by the lens mounted on top or by applying the dust cap supplied along with the product. This precaution is necessary to avoid damaging the sensitive sensor surface. SIMATIC VS 710 A5E00032597-02...
  • Page 24: System Environment

    2. Productive mode The VS 710 is in the target operating mode and receives jobs (or delivers processed data) through digital I/O, RS232, and PROFIBUS-DP interfaces. It communicates with actuators / sensors, control PCs, and PROFIBUS-DP master systems. SIMATIC VS 710 A5E00032597-02...
  • Page 25: Connection Options

    DP interface Yes * Digital I/O Function in Productive Mode Connection via: VS 710 VS 710 OEM ** (with ProVision) RS232 interface DP interface Digital I/O as of ProVision V2.0 ** A suitable user program is required. SIMATIC VS 710 A5E00032597-02...
  • Page 26: Interactive Operation

    The HOSTKEY.COM file is only to be run under the Windows 95, Windows 98 and Windows ME operating systems. The HSTKEYNT.EXE file is only to be run under the Windows NT and Windows 2000 operating systems. SIMATIC VS 710 A5E00032597-02...
  • Page 27: Setup Options

    Activates the COM1 interface with a rate of parameters 115.2 Kbps Operator Input to HOSTKEY Once emulation has been started, key commands go to the VS 710. Exceptions are: – CTRL-X Aborts HOSTKEY – CTRL-Alt-F10 Reboots the VS 710 SIMATIC VS 710 A5E00032597-02...
  • Page 28: Operating Dos 6.22 And Setup

    To do so, try starting INTERSVR.EXE from a suitable AUTOEXEC.BAT (startup file). Time and date settings are lost if the VS 710 is de-energized; for example, if the power supply fails or if you pull the plug. Backups are not made. SIMATIC VS 710 A5E00032597-02...
  • Page 29: Installing Older Provision Versions On Your Vs 710

    The VS 710 must be reset in order to restart it. The remote connection must be disconnected on startup, either by removing the RS232 connection or by exiting HOSTKEY. If the connection is not disconnected, ProVision does not restart and VS 710 returns to the installation mode. SIMATIC VS 710 A5E00032597-02...
  • Page 30: Technical Specifications

    Characteristic Technical Specifications VS 710 Order Number SIMATIC VS 710: 6GF 1710-3AA SIMATIC VS 710 (OEM): 6GF 1710-2AA Dimensions 65 x 80 x 130 mm (W x H x D) with no mounting bracket attached Weight Approx. 0.750 kg (without lens)
  • Page 31 (according to IEC 1000-4-6) 10 V/m With 80% amplitude modulation with 1 kHz, 80 kHz - 1 GHz (according to IEC 1000-4-3) 10 V/m Pulse-modulated 50 % IED with 900 MHz (according to EN 50 204) SIMATIC VS 710 A5E00032597-02...
  • Page 32 6ms, 3 shocks port Semi-sinusoidal: 250 m/s (25 g), 6ms, 1000 shocks Note The absolute brightness values of the image may vary slightly, depending on the physical properties of the CCD chip and the temperature range. SIMATIC VS 710 A5E00032597-02...
  • Page 33: Digital I/O Interface

    Number of simultaneously controllable outputs Isolation Yes (optocoupler) Permitted potential differences 500 VDC Between M connections Between input (M connection) and central grounding point Isolation tested with Interrupt Interrupt Digital inputs 0 and 1 have interrupt capability SIMATIC VS 710 A5E00032597-02...
  • Page 34 Maximum operating frequency: With ohmic load/lamp load 500 Hz With inductive load 2.0 Hz at 0.5 A Max. 400 µs Switching delay Limit (internal) of voltage induced L+-39 V on circuit interruption Short-circuit protection at output Electronic SIMATIC VS 710 A5E00032597-02...
  • Page 35: Certification

    Canadian Standard Association (CSA) in accordance with Stan- dard C22.2 No. 950 or C22.2 No. 142 FM approval in accordance with Factory Mutual Approval Standard Class Number 3611, 3600, 3810 Class I, Division 2, Group A, B, C, D. APPROVED SIMATIC VS 710 A5E00032597-02...
  • Page 36: Fm Approval

    Do not connect or disconnect live circuits unless the location is known to be non-hazardous. Warning WARNING - DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS LOCATION IS KNOWN TO BE NON-HAZARDOUS SIMATIC VS 710 A5E00032597-02...
  • Page 37: Certification For Europe

    Bereich Automatisierungs- und Antriebstechnik A&D AS RD 4 Postfach 1963 D-92209 Amberg Germany Observing the Setup Guidelines The setup guidelines and notes on safety given in the documentation must be observed during startup and when operating the device. SIMATIC VS 710 A5E00032597-02...
  • Page 38 SIMATIC VS710 Quick Reference Guide SIMATIC VS 710 A5E00032597-02...

Table of Contents