ITEM
Fin Material
Fin Type
Heat Exchanger
Row x Stage x FPI
Size (W x H x L)
Material
Air Filter
Type
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
Item
Power Source (Phase, Voltage, Cycle)
Input Power
Starting Current
Running Current
Power Factor
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
Number of core
Power Cord
Length
Thermostat
Protection Device
Note
• Specifications are subject to change without notice for further improvement.
UNIT
INDOOR UNIT
Aluminium (Pre Coat)
Slit Fin
2 x 15 x 21
mm
810 x 315 x 25.4
Polypropelene
One-Touch
Unit
ø
V
Hz
W
A
A
%
A
m
5
OUTDOOR UNIT
Aluminium
Corrugated Fin
2 x 30 x 19
38.1 x 762 x 873.8
Single
230
50
Cooling; 2.12k (350 ~ 2.70k)
Heating; 2.66k (360 ~ 3.20k)
12.5
Cooling; 9.7
Heating; 12.1
Cooling; 95
Heating; 96
14.6
Electronic Control
Electronic Control
903.8