Timer/Clock Setting Display
The time and day must be set at first power on or after
a prolonged power outage. The time must also be set
before the other menus can be accessed.
1. Press
.
2. Press
or
to set current day.
3. Press
to confirm.
4. Repeat steps 2 and 3 to set the current time.
OFF/ON Standby Button
When the unit is ON, operation LED is lit and the
compressor will operate when required. When in
standby the compressor will not operate however the
circulation pump and inline flow boiler can be activated
to provide frost protection.
Operation Mode Button
Press the mode button to cycle through the following
options. A block will be displayed against the
appropriate text on the controller‟s screen.
1.
HEAT ONLY
2.
HEAT + TANK
3.
TANK ONLY
Quiet Operation Button
Reduces the noise of the heat pump by approximately
5dbA for the double fan heat pumps and 3dBA for the
single fan heat pumps by reducing the fan and
compressor speed. This will affect the COP and kW
output.
Inline flow boiler ( Enable / Disable )
The backup heat provides extra heating capacity via
the inline flow boiler. The boiler will only be able to
activate if this option is selected via this button and the
other conditions set with in the controller are met.
When this option is selected the backup heat indicator
will be displayed.
System Check Button
Press
for 5 seconds to enter this mode. Scroll
through using
or
Water inlet temperature
Tank temperature
Compressor running frequency
Error History
Whilst in the check menu, the last error can be reset
by pressing and holding the „Error reset‟ button.
21
Page
to check: