Connectors And Cables; Optical Connection; Sane Ports; Principal And Auxiliary Ports - Optocore X6R-FX-16MI Operating Manual

X6r, v3r-fx series
Table of Contents

Advertisement

Connectors and Cables

Optical Connection

Multimode transceivers connected using a 50 m OM3 fibre cable can be used for applications requiring cable
lengths of up to 700 m (worst case).
Single mode transceivers connected using a 9 m fibre cable can be used for applications requiring cable lengths
of up to 70 km (worst case).
The total optical loss should be less than 6dB between transceivers.
For portable applications, such as touring and other temporary installations, ruggedized HMA Expanded Beam
Connectors, mounted on 1 RU panels and portable cables on cable drums are available.
Please refer to the Product Brochure available at www.optocore.com.

SANE Ports

Use standard, fully wired, twisted pair cable (Cat 5, Cat 5e, Cat 6) terminated with RJ-45 connectors. SANE
utilizes all four pairs of the Cat 5 cable, two pairs for standard Ethernet transmission and two pairs for the SANE
synchronous audio transport. A SANE cable shall not exceed a total cable distance of 100 m.

Principal and Auxiliary Ports

Each of the four channels requires a shielded twisted pair cable.
If two or more channels are wired to the same cable, a common braided shield should enclose the pairs.

RS232-Connection

Use a standard shielded RS232 cable.

Connector Hood Quality

Locking screws for D-Sub connectors should be compatible with 4-40 UNC. Care should be taken in selecting the
right type of connector hoods in order to fulfil the requirements of EMI-radiation directives. Full metal connector
hoods should be used, approved acc. to VDE 0871, FCC 20780 and EMC directive 2004/108/EG, providing
attenuation > 40 dB between 30 MHz up to 1 GHz. The shield of the cable should have contact to the connector
hood.

USB-Connection

Use a USB-A to USB-B cable between the PC and the Optocore device.

LAN-Connection

Use a standard twisted pair cable (Cat-5, Cat-6) with RJ-45 connectors.

Word Clock-Connection

Use 75 -coaxial-cable with BNC-connector.

Mains-Connection

Standard power cords with IEC C13 connectors.